Intel res3tv360 Hardware User'S Manual Download Page 6

Intel® Storage Expander RES3TV360 Hardware User’s Guide

 

iv

 

 

Special  International  Committee  on  Radio  Interference  Compliance  Statement 

(CISPR 22)

 

This product has been found to comply with the requirements of the Information Technology  Equipment -- Radio 
Disturbance Characteristics -- Limits and Methods of  Measurement (CISPR 22).

 

 

European Union Compliance Statement

 

This  Information  Technology  Equipment  has  been  tested  and  found  to  comply  with  EMC  Directive 
89/336/EEC, as amended by 92/31/EEC and 93/68/EEC, in accordance with:

 

•  

EN55022 (1998+A1:2000+A2:2007) Emissions:

 

-

 

Class A ITE radiated and conducted emissions

 

•  

EN55024 (1998+A1:2001+A2:2010) Immunity:

 

– 

EN61000-4-2 (2009) Electrostatic discharge: ±4 kV contact, ±8 kV air

 

– 

EN61000-4-3 (2010) Radiated immunity: 3V/m

 

– 

EN61000-4-4 (2004) Electrical fast transients/burst: ±1 kV AC, ±0.5 kV I/O

 

– 

EN61000-4-5 (2006) Surges: ±1 kV differential mode, ±2 kV common mode

 

– 

EN61000-4-6 (2009) Conducted immunity: 3 V

 

– 

EN61000-4-11 (2004) Supply dips and variations: 30% and 100%

 

 

EN50581 (2012) Technical Documentation:

 

– 

For  the  assessment  of  electrical  and  electronic  products  with  respect  to  the  restriction  of  hazardous 
substances

 

In addition, all equipment requiring U.L. listing has been found to comply with EMC Directive 73/23/EEC as amended 
by 93/68/EEC in accordance with EN60950 with  amendments A1, A2, A3, A4, A11.

 

Australian/New Zealand Compliance Statement

 

This device has been tested and found to comply with the limits for a Class B digital  device, pursuant to the 
Australian/New Zealand standard AS/NZS 3548 set out by the Spectrum Management Agency.

 

Canadian Compliance Statement

 

This Class A digital apparatus meets all requirements of the Canadian Interference -  Causing Equipment 
Regulations (ICES-003).

 

Cet  appareil  numérique  de  la  classe  B  respecte  toutes  les  exigences  du  Règlement sur  le  matériel  brouilleur  du 
Canada (ICES-003).

 

Japanese Compliance (Voluntary Control Council Initiative)

 

This equipment complies to class B Information Technology equipment based on VCCI  (Voluntary Control 
Council for Interface). This equipment is designed for home use but it may cause radio frequency interference 

Summary of Contents for res3tv360

Page 1: ...Intel Storage Expander RES3TV360 Hardware User s Guide Rev 2 1 November 2020 Intel Server Boards and Systems...

Page 2: ...This page is intentionally left blank...

Page 3: ...1 0 Production version Jan 2016 2 0 Applied to the new format Corrected the SAS connector description Corrected verbiage about wide ports Removed reference to activity and fault indicators Nov 2020 2...

Page 4: ...ESS AGAINST ALL CLAIMS COSTS DAMAGES AND EXPENSES AND REASONABLE ATTORNEYS FEES ARISING OUT OF DIRECTLY OR INDIRECTLY ANY CLAIM OF PRODUCT LIABILITY PERSONAL INJURY OR DEATH ARISING IN ANY WAY OUT OF...

Page 5: ...owever if this equipment does cause interference to radio or television equipment reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the int...

Page 6: ...and variations 30 and 100 EN50581 2012 Technical Documentation For the assessment of electrical and electronic products with respect to the restriction of hazardous substances In addition all equipmen...

Page 7: ...ment is home use Class B electromagnetic wave suitability equipment and to be used mainly at home and it can be used in all areas Taiwan Compliance This equipment complies to class B Information Techn...

Page 8: ...ponents 3 3 3 CompatibleDevices 4 3 4 BlockDiagram 4 3 5 Board Dimensions 5 3 6 Mechanical Information 5 3 7 About the Intel Storage Expander Card RES3TV360 6 4 InstallingandConnectingthe Storage Expa...

Page 9: ...ology You should also be familiar with RAID controllers modules expanders and related support devices 1 2 Terminology Used in this Guide Many of the terms and concepts referred to in this guide are kn...

Page 10: ...Hardware The Intel SAS Expander RES3 TV360 is supported on the following server system families and chassis Intel Server System R2000WT Family Intel Server System R2000WF Family Intel Server Chassis P...

Page 11: ...nagement information with expanders Serial Tunneling Protocol STP support for SATAII through expander interfaces SAS protocol described in the Serial Attached SCSI SAS Standard version 2 0 SFF 8485 pr...

Page 12: ...are User s Guide 4 3 3 CompatibleDevices 2 5 inch and 3 5 inch SAS 3 SAS 2 and SATA drives Non disk devices including SAS expanders Support for drives of mixed capacity SAS 3 and SAS 2 host controller...

Page 13: ...nder RES3TV360 Dimension RAID Expander RES3TV360 Height 2 165 Length 8 405 PCB Thickness 0 062 Max Component Height Top Side 0 570 Max Component Height Bottom Side 0 120 3 6 Mechanical Information The...

Page 14: ...RAID expander with these features Form Factor 2 165 x 8 405 Data transfer rate 12 Gb s per port Phys Unified Serial Ports 36 Connectors internal 1 mini SAS HD x1 2 mini SAS HD x4 SFF 8643 36 ports inp...

Page 15: ...r of drives and cables for your application see Section 4 2 Selecting Disk Drives and Cables on Page 9 4 2 Selecting Disk Drives and Cables 4 2 1 Disk Drives Your Storage Expander supports SAS and SAT...

Page 16: ...ion Type Comment A B C D E F I Internal output connectors to backplane or drives SFF 8643 A SAS Output ports 0 3 B SAS Output ports 4 7 C SAS Output ports 8 11 D SAS Output ports 12 15 E SAS Output po...

Page 17: ...touch a grounded metal object before handling the expander card 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For ins...

Page 18: ...expander card and the host SAS or RAID controller Caution Follow the instructions carefully when connecting the connectors from the SAS expander to the connectors on the midplane Each connector is pre...

Page 19: ...xpander RES3TV360 Hardware User s Guide 11 5 Configuring the Storage Expander After physically installed into a server system the RES3TV360 Storage Expander is transparent to users in RAID or non RAID...

Page 20: ...eck the connections to each disk drive power supply LED connector and so on Try disconnecting and reconnecting disk drives from the expander Check that your expander is installed in a compatible PCIe...

Page 21: ...when removing and replacing components Toprevent ESD damage Use an ESD wrist or ankle strap and ensure that it makes skin contact Connect the equipment end of the strap to an unpainted metal surface...

Page 22: ...Relative humidity 20 to 80 non condensing Altitude Up to 3 000 meters The storage and transit environment conditions are Ambient temperature with forced airflow 30 C to 80 C dry bulb Relative humidit...

Reviews: