Intel res3tv360 Hardware User'S Manual Download Page 22

Intel® Storage Expander RES3TV360 Hardware User’s Guide

 

14

 

Appendix B: 

Technical Specifications 

Environmental Specifications

 

Note:  

Your Storage Expander requires adequate airflow to operate reliably. The recommended  airflow is 200 LFM 

(linear feet per minute), minimum to avoid operating above the  maximum ambient temperature. Forced airflow is 
required.

 

The thermal and atmospheric characteristics are:

 

 

Ambient temperature with forced airflow

 

0°C to 55°C

 

Relative humidity

 

20% to 80%, non-condensing

 

Altitude

 

Up to 3,000 meters

 

 

The storage and transit environment conditions are:

 

 

Ambient temperature with forced airflow

 

-30°C to 80°C (dry bulb)

 

Relative humidity

 

5% to 90%, non-condensing

 

 

Note:   

Ambient temperature is measured 1” from the expander processor.

 

DC Power Requirements

 

 

 

Connector

 

Description

 

Requirements

 

4-pin Molex

 

DC Voltage

 

12V

 

 
 

 

 

Product

 

Typical Current

 

Storage Expander RES3TV360

 

1.34A @ 12 VDC

 

Storage Expander RES3TV360

 

All power is supplied through a remote RA 4-
pin  12V  power  connector.  The  +12  V  rail  is 

used  to  generate  the  other required  voltage 
rails  of  3.3V,  1.8V,  1.005V,  and  0.925V  and 
+1.8 V.

 

 

Summary of Contents for res3tv360

Page 1: ...Intel Storage Expander RES3TV360 Hardware User s Guide Rev 2 1 November 2020 Intel Server Boards and Systems...

Page 2: ...This page is intentionally left blank...

Page 3: ...1 0 Production version Jan 2016 2 0 Applied to the new format Corrected the SAS connector description Corrected verbiage about wide ports Removed reference to activity and fault indicators Nov 2020 2...

Page 4: ...ESS AGAINST ALL CLAIMS COSTS DAMAGES AND EXPENSES AND REASONABLE ATTORNEYS FEES ARISING OUT OF DIRECTLY OR INDIRECTLY ANY CLAIM OF PRODUCT LIABILITY PERSONAL INJURY OR DEATH ARISING IN ANY WAY OUT OF...

Page 5: ...owever if this equipment does cause interference to radio or television equipment reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the int...

Page 6: ...and variations 30 and 100 EN50581 2012 Technical Documentation For the assessment of electrical and electronic products with respect to the restriction of hazardous substances In addition all equipmen...

Page 7: ...ment is home use Class B electromagnetic wave suitability equipment and to be used mainly at home and it can be used in all areas Taiwan Compliance This equipment complies to class B Information Techn...

Page 8: ...ponents 3 3 3 CompatibleDevices 4 3 4 BlockDiagram 4 3 5 Board Dimensions 5 3 6 Mechanical Information 5 3 7 About the Intel Storage Expander Card RES3TV360 6 4 InstallingandConnectingthe Storage Expa...

Page 9: ...ology You should also be familiar with RAID controllers modules expanders and related support devices 1 2 Terminology Used in this Guide Many of the terms and concepts referred to in this guide are kn...

Page 10: ...Hardware The Intel SAS Expander RES3 TV360 is supported on the following server system families and chassis Intel Server System R2000WT Family Intel Server System R2000WF Family Intel Server Chassis P...

Page 11: ...nagement information with expanders Serial Tunneling Protocol STP support for SATAII through expander interfaces SAS protocol described in the Serial Attached SCSI SAS Standard version 2 0 SFF 8485 pr...

Page 12: ...are User s Guide 4 3 3 CompatibleDevices 2 5 inch and 3 5 inch SAS 3 SAS 2 and SATA drives Non disk devices including SAS expanders Support for drives of mixed capacity SAS 3 and SAS 2 host controller...

Page 13: ...nder RES3TV360 Dimension RAID Expander RES3TV360 Height 2 165 Length 8 405 PCB Thickness 0 062 Max Component Height Top Side 0 570 Max Component Height Bottom Side 0 120 3 6 Mechanical Information The...

Page 14: ...RAID expander with these features Form Factor 2 165 x 8 405 Data transfer rate 12 Gb s per port Phys Unified Serial Ports 36 Connectors internal 1 mini SAS HD x1 2 mini SAS HD x4 SFF 8643 36 ports inp...

Page 15: ...r of drives and cables for your application see Section 4 2 Selecting Disk Drives and Cables on Page 9 4 2 Selecting Disk Drives and Cables 4 2 1 Disk Drives Your Storage Expander supports SAS and SAT...

Page 16: ...ion Type Comment A B C D E F I Internal output connectors to backplane or drives SFF 8643 A SAS Output ports 0 3 B SAS Output ports 4 7 C SAS Output ports 8 11 D SAS Output ports 12 15 E SAS Output po...

Page 17: ...touch a grounded metal object before handling the expander card 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For ins...

Page 18: ...expander card and the host SAS or RAID controller Caution Follow the instructions carefully when connecting the connectors from the SAS expander to the connectors on the midplane Each connector is pre...

Page 19: ...xpander RES3TV360 Hardware User s Guide 11 5 Configuring the Storage Expander After physically installed into a server system the RES3TV360 Storage Expander is transparent to users in RAID or non RAID...

Page 20: ...eck the connections to each disk drive power supply LED connector and so on Try disconnecting and reconnecting disk drives from the expander Check that your expander is installed in a compatible PCIe...

Page 21: ...when removing and replacing components Toprevent ESD damage Use an ESD wrist or ankle strap and ensure that it makes skin contact Connect the equipment end of the strap to an unpainted metal surface...

Page 22: ...Relative humidity 20 to 80 non condensing Altitude Up to 3 000 meters The storage and transit environment conditions are Ambient temperature with forced airflow 30 C to 80 C dry bulb Relative humidit...

Reviews: