background image

4

General Installation Process

9

Install Memory Modules

DDR3 DIMM Memory Ide

ntification:

Other

Memory

DDR3

CAUTION:  

Observe normal ESD (ElectroStatic 

Discharge) procedures to avoid possible damage to 

system components.

DIMM notch and socket bump must align as shown below.

8

Install Processor Heatsink(s)

NOTE

: Heatsink styles may vary.

Remove the protective film on the TIM if present.

D

  CAUTION: The heatsink has thermal interface 

  material (TIM) on the underside of it. Use caution so 

      that you do not damage the thermal interface material.  

  Use gloves to avoid sharp edges.

E

C

A

B

Align heatsink fins to the front and back of 

the chassis for correct airflow. 

Airflow goes from front-to-back of chassis.

Each heatsink has four captive fasteners and 

should be tightened in a diagonal manner using 

the following procedure:

Using a #2 Phillips* screwdriver, 

start with screw 1 and engage screw 

threads by giving it two rotations 

and stop. (Do not fully tighten.)  
Proceed to screw 2 and engage screw 

threads by giving it two rotations and 

stop. Similarly, engage screws 3 and 4. 

Repeat steps C and D by giving each 

screw two rotations each time until 

each screw is lightly tightened up to 

a maximum of 8 inch-lbs torque.

C

OPEN 1st

CLOSE 1st

Processor

Socket

AIRFLOW

Chassis Front

2

3

1

4

A

B

TIM

D

CAUTION:

Do not 

over-tighten

fasteners.

E

CPU 1 Socket

CPU 2 Socket

CPU 4 Socket

CPU 3 Socket

DIMM_E1

DIMM_E2

DIMM_E3

DIMM_F1

DIMM_F2

DIMM_F3

DIMM_L1

DIMM_L2

DIMM_L3

DIMM_M1

DIMM_M2

DIMM_M3

DIMM_J1

DIMM_J2

DIMM_J3

DIMM_K1

DIMM_K2

DIMM_K3

DIMM_R1

DIMM_R2

DIMM_R3

DIMM_T1

DIMM_T2

DIMM_T3

DIMM_N1

DIMM_N2

DIMM_N3

DIMM_P1

DIMM_P2

DIMM_P3

DIMM_G1

DIMM_G2

DIMM_G3

DIMM_H1

DIMM_H2

DIMM_H3

DIMM_C1

DIMM_C2

DIMM_C3

DIMM_D1

DIMM_D2

DIMM_D3

DIMM_A1

DIMM_A2

DIMM_A3

DIMM_B1

DIMM_B2

DIMM_B3

Install Memory Modules ...continued

Memory Configurations and Population Order:

For best performance, a minimum of four DIMMs per CPU is 

recommended, populated in the blue slot of each memory channel.

In a single-processor configuration, always populate A1 DIMM first.

In a four-processor configuration, always populate A1 DIMM for CPU1, E1 

DIMM first for CPU2, J1 for CPU3, and N1 for CPU4.

NOTE

: For additional memory configurations, see the Service Guide 

available at 

http://www.intel.com/p/en_US/support

.

Memory sizing and configuration is supported only for qualified DIMMs 

approved by Intel

®

. For a list of supported memory, go to: 

http://serverconfigurator.intel.com

.

Intel

® 

Server Board S4600LH2/LT2

Install Processor(s) ...continued

Push down on the locking lever on the 

CLOSE 1st

 side.

F.  Latch the Locking Lever

A
B

Slide the tip of the lever under the notch in the load plate.  

Make sure the load plate tab engages under the socket lever when 

fully closed.

C

Repeat the steps to latch the locking lever on the other side.

OPEN 1st

CLOSE 1st

REMOVE

REMOVE

CLOSE 1st

B

A

OPEN 1st

CLOSE 1st

C

NOTE

: Latch the levers in the 

order as shown.

Summary of Contents for R2000LH2

Page 1: ... If you are not familiar with ESD Electrostatic Discharge procedures used during system integration see the complete ESD procedures described in your Service Guide This guide and other supporting documents are located on the web at http www intel com support G54804 003 Intel Server System R2000LH2 LT2 Product Family Quick Installation User s Guide 3 5 hard drive bay system as shown ...

Page 2: ... This page is intentionally left blank ...

Page 3: ...k s 3 Install Processor s 3 Install Processor Heatsink s 4 Install Memory Modules 4 Install Hard Drives 5 Install Optical Drive 8 Install Intel I O Expansion Module optional 8 Install Intel RAID C600 Upgrade Key optional 8 Install Air Duct 9 Install Add in Card s 9 Install Add in Card Riser Assembly 10 Install Intel RAID Smart Battery optional 10 Install Top Cover 10 Install Power Supply Module 10...

Page 4: ...stalled at all times with or without a processor installed Memory Slot population requirements NOTE Specified memory slots either can be populated with a DIMM or supplied DIMM Blank Memory population rules apply when installing DIMMs DIMM Population Rules on CPU 1 Install DIMMs in order Channels A B C and D Start with first DIMM slot blue on each channel then slot 2 then slot 3 Remove only DIMM bla...

Page 5: ... Upgrade Key installed to be functional O p t i c a l D e v i c e A s s e m b l y Hard Drive Bays System Fans CPU2 CPU 3 Add in Card Riser Assembly 1 1 Redundant Power Supply Modules Server Board Air Duct Optical Drive Bay Front Control Panel CPU1 CPU4 System Features and Components A i r d u c t 3 5 Hard Drive Bay system as shown ...

Page 6: ...cedures before reaching inside to make server board connections or install components CAUTION Unplug all AC power cords and remove all power supply modules before lifting tilt bay Lift up the tilt bay A Bend and slide out the air duct B Remove the air duct from the chassis C O p t i c a l D e v i c e A s s e m b l y A B B C 5 Remove Air Duct O p t i c a l D e v i c e A s s e m b l y B B A 3 Remove...

Page 7: ...n the underside of it Use caution so that you do not damage the thermal interface material Use gloves to avoid sharp edges Using a 2 Phillips screwdriver loosen the four screws located on the heatsink corners in a diagonal manner using the following procedure Using a 2 Phillips screwdriver start with screw 1 and loosen it by giving it two rotations and stop IMPORTANT Do not fully loosen Proceed to...

Page 8: ...ocket CPU 4 Socket CPU 3 Socket DIMM_E1 DIMM_E2 DIMM_E3 DIMM_F1 DIMM_F2 DIMM_F3 DIMM_L1 DIMM_L2 DIMM_L3 DIMM_M1 DIMM_M2 DIMM_M3 DIMM_J1 DIMM_J2 DIMM_J3 DIMM_K1 DIMM_K2 DIMM_K3 DIMM_R1 DIMM_R2 DIMM_R3 DIMM_T1 DIMM_T2 DIMM_T3 DIMM_N1 DIMM_N2 DIMM_N3 DIMM_P1 DIMM_P2 DIMM_P3 DIMM_G1 DIMM_G2 DIMM_G3 DIMM_H1 DIMM_H2 DIMM_H3 DIMM_C1 DIMM_C2 DIMM_C3 DIMM_D1 DIMM_D2 DIMM_D3 DIMM_A1 DIMM_A2 DIMM_A3 DIMM_B1 ...

Page 9: ...only Hard Drive Numbering Diagram Drive 0 Primary 8 x 2 5 hard drive bay as shown A B Press the green latch to unlock Pull out the black lever and slide the carrier out D C Remove the four screws securing the plastic drive blank from the 2 5 HDD carrier Disengage the plastic drive blank from the HDD carrier Remove the plastic drive blank from the 2 5 HDD carrier C D Install the hard disk drive usi...

Page 10: ...k drive using the same four screws as shown Make sure the connector end of the drive matches the backplane connector With the lever open insert the hard disk drive assembly into the chassis Push in the lever to lock it into place d1 Bottom View T O P B R E A K O F F T A B B E F O R E M O U T IN G 2 5 H A R D D R IV E d2 CAUTION If you don t install all drives empty drive bays must be occupied by c...

Page 11: ...e Drive with the four screws C Slide the Solid State Drive carrier into the chassis D Secure the Solid State Drive carrier with the two screws E Connect the cables F Remove the six screws securing the front end module from the chassis A Slide the front end of the module forward a little B Push the front end module into place A Align the rack handle with the two holes on the side of the server syst...

Page 12: ...server board connector NOTE If included remember to install the EMI shield B I O Module A C Install the module to the provided bracket Secure the module to the bracket with the three screws Install the provided connector converter Fix the I O Module to the Bracket before installing it at the left edge of the Board A B C 11 Install Optical Drive A B IMPORTANT NOTE If you do not install a device at ...

Page 13: ...ON Observe normal ESD precautions when installing add in cards Remove the filler panel from the add in card slot and install the provided proper bracket as shown Insert add in card until it sits in the riser connector Secure add in card with screw provided with bracket as shown NOTE Make sure that all empty add in card slots have filler panels installed For Half length PCI Add in Card s For Full l...

Page 14: ...e mounting holes A B O p t i c a l D e v i c e A s s e m b l y A C B 16 Install Add in Card Riser Assembly NOTE Please make sure the release lever is in UP position before installing the add in card riser assembly A Position the riser card connector edge over the server board riser socket and align the riser bracket to the plastic guides on the chassis Press down the release lever to install the r...

Page 15: ...t the appropriate drivers to install On other operating systems browse the CD folders to locate and install the driver files Download the latest version of the Intel System Management Software from http www intel com content www us en server management intel server management html and use the instructions provided at that link to install the software NOTE The FRUSDR utility must be run for full pl...

Page 16: ...t Panel Header J106 Front Panel Video Main Power 2 Main Power 1 IPMB PDB Signal LCP HSBP I2 C Fan Board Power 3 2 Default Password Clear 3 2 Default Password Clear 3 2 Default Password Clear J74 BIOS Recovery J75 BIOS Default 3 2 Default J73 Password Clear Password Clear J81 ME Force Update 3 2 DSR Default DCD J33 Serial A Jumper 3 2 Default Enabled J37 BMC Force Update DIMM_E1 DIMM_E2 DIMM_E3 DIM...

Page 17: ...essories and spares can be found at http www intel com p en_US support O p t i c a l D e v i c e A s s e m b l y 11 10 9 8 AirFlow System Fan Connection System Fan Board FAN 7 FAN 6 FAN 5 FAN 4 FAN 3 FAN 2 FAN 1 FAN 9 FAN 8 FAN 11 FAN 10 ...

Page 18: ...Front Panel Video Front Panel USB GPGPU GPGPU Intel Integrated RAID Module BBU RMFBU2 NOTES To activate the port SCU1 4 7 on the server board a proper Intel RAID C600 Upgrade Key must be installed For instructions see Intel RAID C600 Upgrade Key Installation Guide A second SSD is supported when the optical drive is NOT in use System Cabling Diagram For System with 4 x 3 5 Hard Drive Bay ...

Page 19: ...st be installed For instructions see Intel RAID C600 Upgrade Key Installation Guide A second SSD is supported when the optical drive is NOT in use CPU4 Socket CPU3 Socket CPU1 Socket CPU2 Socket System Fan Board 8 x 2 5 HSBP Power Supply SSD SSD Optical Drive I 2 C HSBP_I2C Front Panel Front Panel Video Front Panel USB Intel Integrated RAID Module BBU RMFBU2 GPGPU GPGPU ...

Page 20: ...G54804 003 ...

Reviews: