Intel® Server D50TNP Family Integration and Service Guide
146
Figure 205. Installing Liquid-Cooled M.2 Cold Plate
12.
If present, peel off the protective film from the thermal interface material of the M.2 cold plate.
13.
Align the cold plate to the riser assembly and slide into place in the direction shown (see Letter A).
14.
Ensure the screw holes are properly aligned (see Letter B) and secure the cold plate to the riser assembly
with a screw (see Letter C).
7.8
Riser Assembly Replacement
The Intel® Server System D50TNP family supports either up to two (1U modules) or up to four (2U modules)
low-profile PCIe* add-in cards.
This section provides assembly and installation procedures for modules that require low-profile add-in card
installation. The following procedures apply to both 1U and 2U modules in both air-cooled and liquid-
cooled configurations.
Note:
The D50TNP Accelerator Module has additional support for up to four full height, full length, double
width PCIe* accelerator cards. Follow the replacement procedures in
Section 7.11
Available Riser Card Options:
•
1U riser card (installed in 1U riser assembly) for 1U module using Intel® Server Board D50TNP1SB
•
1U riser card (installed in 1U riser assembly) for 1U module using Intel® Server Board D50TNP1SBCR
•
2U riser card (installed in 2U riser assembly) for 2U module
Required Tools and Supplies:
•
Anti-static wrist strap and conductive foam pad (recommended)
•
Phillips* head screwdriver #1