Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide
25
3. The RAID firmware presents the virtual drive to the operating system.
RAID Physical Drive Status
Table 7. RAID Physical Drive Status
RAID Virtual Drive Status
Table 8. RAID Virtual Drive Status
Drive State
Code
Description
Unconfigured Good
Unconfigured Good
The drive is functioning normally, but is not part
of a configured virtual drive and is not a hot
spare.
Online
ONLN
The drive is online, is part of a configured virtual
drive, and is functioning normally.
Hot Spare
HOTSP
A physical drive that is configured as a hot spare.
Failed
FAILED
A physical drive that was originally configured as
Online or Hot Spare, but on which the firmware
detects an unrecoverable error.
Rebuilding
REBUILD
A physical drive to which data is being written to
restore full redundancy for a virtual drive.
Unconfigured Bad
Unconfigured Bad
A physical drive on which the firmware detects
an unrecoverable error; the physical drive was
Unconfigured Good or the physical drive could
not be initialized.
Missing
Missing
A physical drive that was online, but which has
been removed from its location.
Offline
Offline
A physical drive that is part of a virtual drive but
which has invalid data as far as the RAID
configuration is concerned.
None
None
A physical drive with an unsupported flag set. An
Unconfigured Good or Offline physical drive that
has completed the 'prepare for removal'
operation.
Drive State
Code
Description
Optimal
Optimal
The drive operating system is good. All config-
ured drives are online.
Degraded
Degraded
The drive operating condition is not optimal
because one of the configured drives has failed
or is offline.
Offline
Offline
The drive is not available to the operating system
and is unusable.
Summary of Contents for AXXRMS2AF040
Page 4: ...iv Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Page 8: ...viii Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Page 10: ...x Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Page 16: ...6 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Page 48: ...38 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Page 50: ...40 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...