background image

Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide

21

Array Performance Features

Table 5. Array Performance Features

SATA bus speed

Upto 6 Gbps per port, point-to-point 

SAS/SATA ports

4 internal ports, 16 devices

Physical and virtual drive 
support

Up to 64 physical drives including up to 16 physical drives in 
up to 16 RAID arrays per controller.
Drives not configured as part of a RAID array can be 
configured as “pass through” drives in Non-RAID mode.  

Firmware

16 MB in reflashable flash ROM

Compatible devices

.5-inch and 3.5-inch SAS or SATA II drives including SSD 
drives

Non disk devices including expanders

Can support drives of mixed capacity  

Cabling

Small thin cables that do not restrict airflow and Shared 
connectors for multiple drives 

Redundant configuration

32 KB NVRAM and config-on-disk (COD) 

Enclosure management

In-band and out-of-band SES2; out-of-band SGPIO

Enclosure support

Assumes one SEP per enclosure

Specification

Intel

®

 Integrated RAID Module RMS2AF040 and 

RMS2AF080

Specification

Intel

®

 Integrated RAID Module RMS2AF040 and 

RMS2AF080

Host data transfer rate

Upto 5.0 Gigabit/sec per PCI Express* lane

Drive data transfer rate

Upto 6 Gigabit/sec per lane

Maximum scatter/gather

80 elements

Maximum size of I/O requests

6.4 Mbytes in 64 Kbyte stripes

Maximum queue tags per 
drive

As many as the drive can accept

Strip size

8, 16, 32, or 64 KB 

Maximum concurrent 
commands

1024 - 16

Support for multiple initiators

Yes 

Performance

Native command queuing

Summary of Contents for AXXRMS2AF040

Page 1: ...Intel Integrated RAID Module RMS2AF040 AXXRMS2AF040 and RMS2AF080 AXXRMS2AF080 Hardware User s Guide Intel Order Number E93119 002...

Page 2: ...SE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel p...

Page 3: ...ineers who are designing an Intel RAID Module RMS2AF040 or RMS2AF080 for their RAID system Anyone installing an Intel RAID Module RMS2AF040 or RMS2AF080 in their RAID system Organization This document...

Page 4: ...iv Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Page 5: ...dware Installation 7 Requirements 7 Installing the RAID Module 7 Configuring the RAID Module 10 Replacing a Controller Resolving a Config Mismatch 10 Intel Integrated RAID Module RMS2AF0x0 Characteris...

Page 6: ...t 24 RAID Functionality and Features 24 Hierarchy 24 SAS Bus and ID Mapping 26 A Drive Roaming and Drive Migration Install 27 Drive Roaming 27 Drive Migration 28 B Installation Assembly Safety Instruc...

Page 7: ...ted RAID Module RMS2AF0x0 8 Figure 3 Connecting Cable between the RAID Module and Drives Backplane 9 Figure 4 Card Layout 11 Figure 5 RMS2AF040 Hardware Block Diagram 13 Figure 6 RMS2AF080 Hardware Bl...

Page 8: ...viii Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Page 9: ...1 Jumper Description 12 Table 2 SAS SATA Connector Pin out 17 Table 3 Host Board Interface Connector Pin Out 19 Table 4 Technical Specifications 20 Table 5 Array Performance Features 21 Table 6 Fault...

Page 10: ...x Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Page 11: ...onnectors lower pin counts and lower power requirements than parallel SCSI Benefits of SAS and SATA SAS is a serial point to point enterprise level device interface that leverages the proven SCSI prot...

Page 12: ...r Board S5520UR Intel Server Board S5520HC S5520HCT Intel Server Board S5500HCV Intel Workstation Board S5520SC Intel Server Board S3420GP Intel Server System SR1600UR Intel Server System SR2600UR Int...

Page 13: ...server board See the Tested operating system list for your server board at http www intel com support go motherboards server index htm To make sure the RAID module supports your operating system see...

Page 14: ...to the drive for a missing drive to be marked as failed Auto resume on reboot of initialization or rebuild must be enabled before virtual disk creation Smart initialization automatically checks consis...

Page 15: ...r Chip Online Capacity Expansion and RAID Level Migration Rules Migration must occur to the same or larger capacity configuration Migration cannot occur if there is more than one virtual disk in an ar...

Page 16: ...6 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Page 17: ...low these steps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your server system documentation 3...

Page 18: ...regarding connecting the recommended Right angle end or Vertical end of the SAS SATA cable to the SAS connectors of the controller see your server workstation board or chassis documentation Make sure...

Page 19: ...Route SAS cables carefully Use only straight SAS cables not cross over SAS cables Figure 3 Connecting Cable between the RAID Module and Drives Backplane 7 Install the server system cover and connect t...

Page 20: ...odule follows the PCI slot scanning order used by the server board 3 Follow the instructions in the Intel RAID Software User s Guide Document Number D29305 0xx to configure the RAID module and to inst...

Page 21: ...Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide 11 3 Intel Integrated RAID Module RMS2AF0x0 Characteristics Figure 4 Card Layout AF003490 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11...

Page 22: ...SAS SATA Port 3 J5 SAS SATA Port 4 J6 SAS SATA Port 5 J7 SAS SATA Port 6 J8 SAS SATA Port 7 J5 J8 Ports 4 7 are only available on Intel RAID Module RMS2AF080 J9 Keyed SGPIO Connector 4 pin keyed conne...

Page 23: ...Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide 13 Figure 5 RMS2AF040 Hardware Block Diagram...

Page 24: ...provides eight independent PHYs Intel Intergrade RAID Module RMS2AF040 provides four independent PHYs each supporting 6Gb s and 3Gb s SAS data transfers per PHY Supports SSP to enable communication wi...

Page 25: ...I LSISAS2008 Processor Chip before the server board configures the PCI Express registers The bootstrap ROM sets the Phase Lock Loop PLL dividers bootstrap configuration and so on NVSRAM A 32 KB NVSRAM...

Page 26: ...SAS SATA Connector Pin out The SAS SATA connector shown in the following figure is the standard 7 pin SATA internal connector used by the Intel Integrated RAID Module RMS2AF040 and RMS2AF080 These pin...

Page 27: ...Guide 17 Table 2 SAS SATA Connector Pin out Figure 9 SAS SATA Cable Pin Signal Description 1 GND Ground 2 TX0 Transmitter differential pair 3 TX0 Transmitter differential pair 4 GND Ground 5 RXD Rece...

Page 28: ...ntel Integrated RAID Module RMS2AF040 and RMS2AF080 board interfaces with the host system through a custom board to board interface that implements x8 PCI Express lanes signaling as defined in the PCI...

Page 29: ...ST_PWRGD_PS_R 3 5 TP_FW_SW_RAID_MODE 4 7 GND 5 9 PE0_TX_DP0 6 11 PE0_TX_DN0 7 13 GND 8 15 GND 9 17 PE0_TX_DP1 10 19 PE0_TX_DN1 11 21 GND 12 23 GND 13 25 PE0_TX_DP2 14 27 PE0_TX_DN2 15 29 GND 16 31 GND...

Page 30: ...PE0_RX_DP3 41 32 PE0_RX_DN3 42 34 GND 43 36 GND 44 38 CLK_100M_IOP_DP 45 40 CLK_100M_IOP_D N 46 42 GND 47 44 LED_HDD_ACT_N 48 46 P3V3 49 48 P3V3 50 50 P3V3 Server Connector Pin Number RAID Module Pin...

Page 31: ...drives of mixed capacity Cabling Small thin cables that do not restrict airflow and Shared connectors for multiple drives Redundant configuration 32 KB NVRAM and config on disk COD Enclosure manageme...

Page 32: ...egrated RAID Module RMS2AF040 and RMS2AF080 Self Monitoring Analysis and Reporting Technology SMART support Detects up to 70 of predictable disk drive failures Monitors the internal performance of all...

Page 33: ...irflow must be at least 200 linear feet per minute SFPM to avoid operating above the maximum ambient temperature The storage and transit environment conditions are Temperature range from 30 C to 80 C...

Page 34: ...port for these devices will be determined as they become available For information on support for non hard drive devices see the Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Tested Hardware an...

Page 35: ...to which data is being written to restore full redundancy for a virtual drive Unconfigured Bad Unconfigured Bad A physical drive on which the firmware detects an unrecoverable error the physical driv...

Page 36: ...RMS2AF080 Hardware User s Guide RAID Controller Drive Limitations Only drives that comply with the SAS and SATA specification extensions are supported SAS Bus and ID Mapping Devices on the SAS bus ar...

Page 37: ...esume To use drive roaming follow these steps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your...

Page 38: ...Turn off the power to the system all drives enclosures and system components Remove the power cord s 3 Remove the server cover For instructions see your server system documentation 4 Disconnect the c...

Page 39: ...s To help protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests o...

Page 40: ...r To prevent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted m...

Page 41: ...l and disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassi...

Page 42: ...aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollt...

Page 43: ...mponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten install...

Page 44: ...composants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est...

Page 45: ...ca del equipo y ser de f cil acceso INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos...

Page 46: ...sistema y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento...

Page 47: ...dal retro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento d...

Page 48: ...38 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Page 49: ...Information Product Safety and EMC Compliance This Intel RAID Module has been evaluated for regulatory compliance as an Intel end system and is included as part of the end system certification For in...

Page 50: ...40 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Reviews: