80960HA/HD/HT
Datasheet
19
CLKIN
I
CLOCK INPUT provides the time base for the 80960Hx. All internal circuitry is
synchronized to CLKIN. All input and output timings are specified relative to
CLKIN.
For the 80960HD, the 2x internal clock is derived by multiplying the CLKIN
frequency by two. For the 80960HT, the 3x internal clock is derived by multiplying
the CLKIN frequency by three.
RESET
I
A(L)
RESET forces the device into reset. RESET causes all external and internal
signals to return to their reset state (when defined). The rising edge of RESET
starts the processor boot sequence.
STEST
I
S(L)
SELF TEST, when asserted during the rising edge of RESET, causes the
processor to execute its built in self-test.
FAIL
O
H(Q)
B(Q)
R(0)
FAIL indicates a failure of the processor’s built-in self-test performed during
initialization. FAIL is asserted immediately out of reset and toggles during self-test
to indicate the status of individual tests. When self-test passes, FAIL is de-
asserted and the processor branches to the user’s initialization code. When self-
test fails, the FAIL pin asserts and the processor ceases execution.
ONCE
I
ON-CIRCUIT EMULATION control: the processor samples this pin during reset.
When it is asserted low at the end of reset, the processor enters ONCE mode. In
ONCE mode, the processor stops all clocks and floats all output pins except the
TDO pin. ONCE uses an internal pull-up resistor; see R
PU
definition in
Table 22,
“80960Hx DC Characteristics” on page 40
. Pull this pin high when not in use.
TCK
I
TEST CLOCK provides the clocking function for IEEE 1149.1 Boundary Scan
testing.
TDI
I
TEST DATA INPUT is the serial input pin for IEEE 1149.1 Boundary Scan testing.
TDI uses an internal pull-up resistor; see R
PU
definition in
Table 22, “80960Hx DC
Characteristics” on page 40
.
TDO
O
TEST DATA OUTPUT is the serial output pin for IEEE 1149.1 Boundary Scan
testing. ONCE does not disable this pin.
TRST
I
TEST RESET asynchronously resets the Test Access Port (TAP) controller. TRST
must be held low at least 10,000 clock cycles after power-up. One method is to
provide TRST with a separate power-on-reset circuit. TRST includes an internal
pull-up resistor; see R
PU
definition in
Table 22, “80960Hx DC Characteristics” on
page 40
. Pull this pin low when not in use.
TMS
I
TEST MODE SELECT is sampled at the rising edge of TCK. TCK controls the
sequence of TAP controller state changes for IEEE 1149.1 Boundary Scan
testing. TMS uses an internal pull-up resistor; see R
PU
definition in
Table 22,
“80960Hx DC Characteristics” on page 40
.
VCC5
I
5 V REFERENCE VOLTAGE input is the reference voltage for the 5 V-tolerant I/O
buffers. Connect this signal to +5 V for use with inputs which exceed 3.3 V. When
all inputs are from 3.3 V components, connect this signal to 3.3 V.
VCCPLL
I
PLL VOLTAGE is the +3.3 VDC analog input for the PLL.
VOLDET
O
VOLTAGE DETECT signal allows external system logic to distinguish between a
5 V 80960Cx processor and the 3.3 V 80960Hx processor. This signal is active
low for a 3.3 V 80960Hx (it is high impedance for 5 V 80960Cx). This pin is
available only on the PGA version.
0 = 80960Hx
1 = 80960Cx
Table 7. 80960Hx Processor Family Pin Descriptions (Sheet 4 of 4)
Name
Type
Description