provides a minimum power according to the following table:
Minimum output power
Model of control unit
Fitting diameter
Estimated generator output power
I Fuse 60
20 - 75 mm /
≅
0.7 – 3 in
2 KW
90 - 160 mm /
≅
>3 – 6 in
3,2 KW
180 - 400 mm /
≅
>6 – 16 in
5 KW
I Fuse 105
20 - 75 mm /
≅
0.7 – 3 in
2 KW
90 - 160 mm /
≅
>3 – 6 in
3,2 KW
180 - 500 mm /
≅
>6 – 20 in
5 KW
560 - 1200 mm /
≅
>20 – 48 in
7 KW
18) Warning on generators use
•
Turn on the generator, when it will be stable insert ECU plug into the electrical generator’s outlet.
•
Do not connect other machines or electrical equipment to the generator when the ECU is connected.
•
Unplug ECU
before
turning off the generator.
•
The efficiency of the generator will decrease by 10% every 1000m / 3281 ft in height.
•
Check the fuel level before starting the
fusion process
.