USER MANUAL
–
OPTIMA-33 10K/20K/30K
www.xmart-ups.com
170502-OPTIMA-33 10K/20K/30K (ENGLISH) - 18
8.- OPERATION INTERFACE
UPS FRONT PANEL: PUSH BUTTON
TOWER FRONT PANEL
ON / ENTER
POWER ON
: Keep selected during 1 second to power UPS ON.
ENTER
: It Works as “ENTER” or confirmation function when LCD is in configuration menu mode.
OFF / ESCAPE
POWER OFF
: Keep selected to turn UPS OFF.
ESCAPE
: It Works as ESCAPE key when LCD is in configuration menu mode.
TEST / UP
BATTERY TEST
: When UPS is in normal mode by selecting TEST key UPS enters into battery test mode during 10 seconds.
UP
: It Works as UP key when LCD is in configuration menu mode.
MUTE / DOWN
ALARM MUTE
: It mutes alarm beep in progress.
DOWN
: It Works as DOWN key when LCD is in configuration menu mode,
TEST / UP + MUTE / DOWN - Simultaneous Activation
CONFIGURATION MODE
: UPS enters into configuration menu when these 2 keys are activated at same time during 1 second.