Summary of Contents for 1KRS

Page 1: ...1 H series array online UPS 1 6KRS L U U Us s se e er r r s s s m m ma a an n nu u ua a al l l PDF pdfFactory Pro www fineprint cn...

Page 2: ...2 Rear panel 5 4 Maintenance 7 4 1 Operation environment 7 4 2 Battery application 7 4 3 Trouble shooting 7 5 Technical data 8 5 1 Electrical specifications 8 5 2 Typical stored energy time 8 5 3 Mech...

Page 3: ...quipment which would overload the UPS system e g laser printers to the UPS output socket Place cables in such a way that no one can step on or trip over them Do not connect domestic appliances such as...

Page 4: ...s voltages may occur between the battery terminals and the ground Before touching any operation please verify that no voltage is present Batteries may cause electric shock and have a high short circui...

Page 5: ...e mains power via the bypass Alarm LED Lights up when the UPS system is in fault condition at the same time an acoustic warning signal is issued every second Indicator Load level signaled when the AC...

Page 6: ...6 1KRL 2KRL 3KRL PDF pdfFactory Pro www fineprint cn...

Page 7: ...lable wiring can be completed by professional electrician Note terminal cover should be put back for safety reason after wiring completed Input breaker if the breaker pops out off reduce the load on t...

Page 8: ...ration to the UPS for long time then the battery must be charged every three month 4 3 Trouble shooting Using the table below some common problems can be solved If the problem still exists or some pro...

Page 9: ...at 25 C in minutes Model 100 load 50 load 1K 5 14 2K 9 21 3K 5 15 6K 8 23 5 3 Mechanical data Model Net weight Kg Dimension mm 1KS 16 3 1KL 9 1 Battery pack 36V 22 5 2KL 11 5 3KL 12 3 Depth 450 Batter...

Page 10: ...proprietary command sequence to monitor the utility power and UPS status and to control the UPS output The data format of RS232 is listed as followed Baud rate 2400 bps Data length 8 bits Ending bit 1...

Page 11: ...or for details The following is the pin assignment and description of DB 9 connector inAS400 card Pin Description I O type 1 UPS failure Output 2 Summary alarm Output 3 GND 4 Remote shutdown Input 5 C...