Frequency 

46Hz~54Hz/56Hz~64Hz 

Amperage 

(maximum ) 

5A(L mode 7A) 10A(L mode 12A)  15A(L mode 16A)

30A 

Output 

Power rating 

1KVA/0.7KW 

2KVA/1.4KW 

3KVA/2.1KW 

6KVA/4.2KW 

Voltage 

220/230/240VAC 

Frequency 

50/60Hzx(1

±

0.2%), battery mode 

50/60Hzx(1

±

0.1%), 

battery mode 

Wave form 

Sinusoidal 

Batteries(standard) 

Number and type 

3x12V/7.2AH 

8x12V/7.2AH 

20x12V/7.2AH 

 

5.2. Typical stored energy time

 (battery mode) 

 

Typical values at 25

°

C in minutes: 

 

Model 

100% load 

50% load 

1K 

14 

2K 

21 

3K 

15 

6K 

23 

 

5.3. Mechanical data 
 

Model 

Net weight(Kg) 

Dimension(mm) 

1KS 

16.3 

1KL 

9.1 

Battery pack 36V 

22.5 

2KL 

11.5 

3KL 

12.3 

Depth: 450 

Battery pack 96V 

27.8 

Battery pack 240V 

64.2 

 

Depth: 600 

 

 

5.4. CE conformity 

 

1KRS(L)/2KRL/3KRL 

 

Ø

 

Safety: EN62040-1-1:2003 

Ø

 

Conducted emission: EN50091-2    Class B 

Ø

 

Radiated emission: EN50091-2    Class B 

Ø

 

Harmonic current: EN61000-3-2 

Ø

 

Voltage fluctuations and flicker: EN61000-3-3 

 

EMS 

EN61000-4-2(ESD) 

Level 4 

 

EN61000-4-3(RS) 

Level 3 

 

EN61000-4-4(EFT) 

Level 4 

 

EN61000-4-5(lighting surge) 

Level 4 

 

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

Summary of Contents for 1KRS

Page 1: ...1 H series array online UPS 1 6KRS L U U Us s se e er r r s s s m m ma a an n nu u ua a al l l PDF pdfFactory Pro www fineprint cn...

Page 2: ...2 Rear panel 5 4 Maintenance 7 4 1 Operation environment 7 4 2 Battery application 7 4 3 Trouble shooting 7 5 Technical data 8 5 1 Electrical specifications 8 5 2 Typical stored energy time 8 5 3 Mech...

Page 3: ...quipment which would overload the UPS system e g laser printers to the UPS output socket Place cables in such a way that no one can step on or trip over them Do not connect domestic appliances such as...

Page 4: ...s voltages may occur between the battery terminals and the ground Before touching any operation please verify that no voltage is present Batteries may cause electric shock and have a high short circui...

Page 5: ...e mains power via the bypass Alarm LED Lights up when the UPS system is in fault condition at the same time an acoustic warning signal is issued every second Indicator Load level signaled when the AC...

Page 6: ...6 1KRL 2KRL 3KRL PDF pdfFactory Pro www fineprint cn...

Page 7: ...lable wiring can be completed by professional electrician Note terminal cover should be put back for safety reason after wiring completed Input breaker if the breaker pops out off reduce the load on t...

Page 8: ...ration to the UPS for long time then the battery must be charged every three month 4 3 Trouble shooting Using the table below some common problems can be solved If the problem still exists or some pro...

Page 9: ...at 25 C in minutes Model 100 load 50 load 1K 5 14 2K 9 21 3K 5 15 6K 8 23 5 3 Mechanical data Model Net weight Kg Dimension mm 1KS 16 3 1KL 9 1 Battery pack 36V 22 5 2KL 11 5 3KL 12 3 Depth 450 Batter...

Page 10: ...proprietary command sequence to monitor the utility power and UPS status and to control the UPS output The data format of RS232 is listed as followed Baud rate 2400 bps Data length 8 bits Ending bit 1...

Page 11: ...or for details The following is the pin assignment and description of DB 9 connector inAS400 card Pin Description I O type 1 UPS failure Output 2 Summary alarm Output 3 GND 4 Remote shutdown Input 5 C...

Reviews: