USER MANUAL
–
OPTIMA-33 10K/20K/30K
www.xmart-ups.com
170502-OPTIMA-33 10K/20K/30K (ENGLISH) - 2
SAFETY STANDARDS
SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC)
UPS Part 1-1: General & Safety UPS in accessible areas
IEC/EN 62040-1
ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE (2004/108/EC)
UPS, Part 2, Electromagnetic Compatibility: Radiated & Conducted
IEC/EN 62040-2
(Cat 3)
Low Freq. Conducted Disturbances & Signals:
IEC/EN 61000-2-2
Electrostatic discharge immunity Test:
IEC/EN 61000-4-2 (Level 4)
Radiated radio Frequency immunity:
IEC/EN 61000-4-3 (Level 3)
Electrical Fast Transient / burst immunity:
IEC/EN 61000-4-4 (Level 4)
Surge immunity:
IEC/EN 61000-4-5 (Level 4)
Conducted Immunity:
IEC/EN 61000-4-6 (Level 3)
Power frequency magnetic field immunity:
IEC/EN 61000-4-8 (Level 4)
PERFORMANCE:
UPS Part 3: Methods of operation, specifications and test requirement
IEC/EN 62040-3
IT Equipment. SAFETY. Part 1: General Requirements
IEC/EN 60950-1
BATTERY SAFETY
EN 50272
CE
CE compliant
UL1778 (for UL models only)
UL1778 compliant (by cTUV-US)
IP PROTECTION
IP20 (static)
QUALITY MANAGEMENT:
Manufactured under:
ISO 9001 : 2000
ENVIRONMENTAL MANAGEMENT:
Manufactured under:
ISO 14001 : 2004
TRANSPORTATION:
IEC/EN 300019-2-2, Class 2.3
WARNING: Modifications made on the product or the use of this product as a part of a more complex system not expressly approved by
th
e party responsible for compliance could void the user’s authority to operate the equipment. It also could affect its perform
ance and
the compliance of regulations. XMART is not responsible of modifications made after manufacturing.
WARNING: This is a category C3 UPS product. This category includes UPS with an output current exceeding 16A and intended for use in
the second environment. Such UPS are suitable for use in commercial or industrial installations having a minimum boundary of 30m
from other buildings classified as first environment. Category C3 UPS shall meet category C3- UPS emission limits and withstand the
immunity requirements of above table.
WARNING: This is a product for commercial and industrial applications in the second environment. Installation restrictions or additional
measures may be needed to prevent disturbances.
DEFINITIONS:
First Environments: Those sites directly connected without intermediate transformers to the public low-voltage mains supply, like
residential buildings and small companies.
Second Environments: Those sites not connected directly to public low-voltage mains that supplies residential buildings like industries
and big companies powered by its own intermediate transformer.