TwinLock B670/C690 CashProtect DS
Glossary
Manual V.1.01B
98
For every lock there is exactly one master code assigned to user no. 00 (lock master).
This code can be stored in the lock. With it, lock users can be administered. Ex works
the master code for locks of VdS class 2 is
‘
123456
’
and for locks of class 3 it is
‘
12345678
’
. Via user matrix of the optional PC software CashProtectPro, the
system
manager
can define whether the bearer of the master code can also open the lock.
Menu keys
Four keys,
CLEAR
,
<
,
>
and
ENTER
, directly below the display of the operating unit,
to be used for menu navigation.
Open period
See
Blocked Period / Open Period (Time Program)
.
Pairing
Only with firmware version 25/26 and higher. "Pairing" is a procedure that ensures
that the communication between and QPad, the locks and, as it may be, TwinIP is
encrypted and that these units cannot be exchanged without authorisation. See
„Setting Up “Pairing”“
on p. 60 and, as it may be, the TwinIP manual.
Parallel code
Option, which can be selected only with systems with at least two locks. The first
user to open can open lock 1 or lock 2. The second user to open can open the lock
still closed. It is not possible for one user to open all locks.
Can be combined with
‘
Forced sequence
’
. With two locks in the system, one user
can open locks single-handedly during a
‘
Part Lock Time
’
.
If you select this option via PC software, the software will switch off option
‘
Dual
Code
’
automatically.
Part lock(ed) time (3 periods per day)
Before activating a part lock time, make sure that time, day of week and date are set
correctly. For systems with two locks, you can define three periods of
‘
Part lock time
’
per day via software CashProtectPro (optional accessory). During the periods of part
lock time only lock 2 closes, lock 1 remains open. While a period of part lock time
lasts, every attempt at closing lock 1 is cancelled.
Default setting:
‘
Part lock time
’
off.
In order to close lock 1 in spite of active
‘
Part lock time
’
:
Press key
ENTER
while
Close | lock 1
Partly locked!
is displayed. Lock 1
is closed,
‘
Part lock time
’
is suspended for this single closing process.
You can combine option
‘
Part lock time
’
with option
‘
Automatic closing with door
switch
’
. If you do that, lock 1 will stay open during part lock time and will be closed
when it ends.
PIN code
Secret sequence of numerical digits, which users enter at the operating unit.
Sequence of numbers known only by the user or by the lock master, too, which the
user uses for his authentication in the system, an alternative or an optional
complement to
code card
.
Protocol (event log)
All important events are logged chronologically with date and time. The protocol can
be exported, depending on the system version also online. Devices and users
involved in an event are listed. The latest 10,000 events are logged. Events are
programming processes, system errors, important status messages and attempted
acts of sabotage and manipulation. The complete event log memory can be
transferred via USB and displayed as well as printed via PC software CashProtectPro.