Technical Data
MoRoS LAN PRO 2.0
10
4
Technical Data
4.1
Physical Features
Danger!
Overvoltage.
Fire hazard!
The MoRoS LAN PRO 2.0 must be secured with a suitable
fuse against overvoltage.
All specified data was measured with nominal input voltage, at full load, and an ambient
temperature of 25 . The limit value tolerances are subject to the usual variations.
Physical Feature
Value
Operating voltage
minimum 10 V DC
maximum 60 V DC
Power consumption idle
2 W
Power consumption connection
3 W
Level inputs
HIGH level = 3-12 V (contact open or volt-
age strength for external supply)
LOW level = 0-1 V
Current consumption of an active input
against GND (in5V)
Typically 0.35 mA
Switch output, maximum switch voltage
30 V (DC) / 42 V (AC)
Switch output, maximum current load
1 A (DC) / 0.5 A (AC)
Weight
300 g
Dimensions (Width x Depth x Height)
70 mm x 110 mm 75 mm
Temperature range
-20°C – 55°C
Maximum permissible humidity
95% non-condensing
IP rating
Housing IP40, Terminals IP20
Table 1: Physical Features