EloStar time
Handbuch
Version 1.03
19
3.12.3. Automatic locking with the door switch
Notes:
•
With the function “Automatic locking via door switch”, the electronic lock can
be automatically locked by actuating a door or boltwork switch.
•
If the door switch is not opened within 15 seconds after the code is entered
and the lock is opened, the electronic lock locks again automatically.
•
The “Automatic locking” function can also be programmed with the PC
software CombiComm.
Activation of the function “Automatic locking via door switch”
*9*
Enter program number 9
123456 *
1
Enter the
master code
10*
1
Enter the
function number
(e.g. 10)
Connect the door switch to IN1
3.12.4. External release / blocking
Notes:
•
The electronic lock can be blocked or released by an external signal, e.g. by a
burglar alarm system, via this input contact. The lock can then no longer be
operated by a user.
•
The function can either be programmed to IN1 or IN2, see function numbers.
Activation of the function “External blocking / release”
*9*
Enter program number 9
123456 *
1
Enter the
master code
30*
1
Enter the
function number
(e.g. 30)
Connect the blocking signal to IN1