EloStar time
Handbuch
Version 1.03
17
Activation of IO functions
Notes:
After activation, the following inputs/outputs are queried or actuated.
Activation or deactivation can only be performed by the master.
The activation or deactivation is saved in the event log.
*9*
Enter program number 9
123456 *
1
Enter the
master code
11*
1
Enter the
function number
(e.g. 11)
2nd digit => outputs
1st digit => inputs
Explanation of the function numbers:
Inputs:
1st digit
0
= No function
1
= Door switch (IN1)
2
= Door switch (IN1), release/blocking (IN2)
3
= Release/blocking (IN1)
Outputs:
2nd digit
0
= No function
1
= Deadbolt status (OUT1)
2
= Silent alarm (OUT1)
3
= Silent alarm (OUT1), deadbolt status (OUT2)
4
= Silent alarm (OUT1), end of opening delay (OUT2)
5
= Deadbolt state (OUT1), end of opening delay (OUT2)
Deleting I/O functions
*9*
Enter program number 9
123456 *
1
Enter the master code
00*
1
Delete = 00 *