![INSTROTECH 6004BW Manual Download Page 49](http://html1.mh-extra.com/html/instrotech/6004bw/6004bw_manual_2070157049.webp)
Service Menu
Function Block Number 18
18.
- DISPLAYS -
To view or alter the displays selection press Enter when the DISPLAYS function block is
displayed. All values can be inserted or altered when highlighted. Do not press enter until all
required changes to the entire block are completed.
The Displays function block allows you to select what you want the Main LED display to be as
well as up to four selections for the LCD graphics display. In most common uses for the
Loadcell transmitter and Bagfiller the Main display would be Gross, with a Beltweigher and
Loss-in-weight transmitter it would be Rate, a Throughput weigher Total and the
Dynamometer would be kW or HP.
The auxiliary LCD display can be used for a group of other useful values such as (for LCT)
net, analog output, mV, excitation voltage,.. (Beltweigher) belt speed, (Loss-in-weight) gross
[bin contents], (Throughput) non-resettable total, (Bagweigher) bag total, (Dynamometer)
RPM & torque and (Batchweigher) aggregate and water values.
Note that if PI Control (Service menu function block 19) is selected then the first line of the
auxiliary LCD automatically becomes Manual Output (00.0-99.9%) and the next line becomes
Auto Setpoint 000,000 . These values can be changed in the Setpoint Values menu, hold
down arrow 3 seconds (or set F1-4 for setpoint values) and you go into Operator's menu
(observe Security Level). Values can be keyed in and entered when in run mode.
If Preset Tare (Service menu, function block 9) is selected then the Pretare Value will be
displayed on the first line. The value can be keyed in and entered in Setpoint Values when in
run mode. Select F1-4 for Setpoint Values.
Default displays
Main
Aux1
Aux2
Aux3
Aux4
Loadcell Transmitter
Gross
Net
Ex Volts
mV
A Out
Suggested displays for other applications
Lo PI Control
Gross
Man %
Auto SP
None
A Out
Loadcell Tx + Pretare
Gross
Pretare
None
None
A Out
Beltweigher
Rate
Total
Reset Total
Beltspeed
A Out
Beltw PI
Rate
Man %
Auto SP
Total
Out
Loss-in-Weight Tx
Rate
Gross
Total
Reset Total
A Out
L-in-W + PI Control
Rate
Man %
Auto SP
Gross
A Out
Throughput Weigher
Total
Reset Total
Gross
None
None
Dynamometer
kW
kW
RPM
Nm
None
Bag Filler
Total
Reset Total
Gross
None
None
Batch Weigher
Gross
Net
Total
Reset Total
None
When the entire block is ready press Enter . This will set the whole block and move on to
the next block, in this case PI CONTROL.
Page