![INSTROTECH 6004BW Manual Download Page 47](http://html1.mh-extra.com/html/instrotech/6004bw/6004bw_manual_2070157047.webp)
Service Menu
Function Block Number 17
17.
- DIGITAL INPUTS -
To view or alter the digital inputs press Enter when the DIGITAL INPUTS function block is displayed. All
values can be inserted or altered when highlighted. Do not press enter until all required changes to the
entire block are completed.
Digital Inputs (D1-6) are inputs from remote potential free contacts. Contact closure activates the input. For
use with rugged pushbuttons (instead of the keypad) or for interlocks
Each input can be individually selected for a number of functions such as :-
No function, Tare, Toggle net/gross, Print, SP latch reset, Reset max value, Reset min value, Reset
max/min, Reset total 1, Set setpoints, Pretare, PI man/auto, PI start, PI stop, PI increase, PI decrease, Belt
zero, LIW start, LIW stop, TP start, TP stop, TP residual, TP interlock, Zero trim, Dyna power, Dyna RPM,
Dyna torque, Bag start, Bag stop, Bag interlock, Bag footswitch, Bag pproduct sense, Bat start, Bat stop,
Bat add water, Bat change A-D, Bat set SPs,.....
Default inputs
D1
D2
D3
D4
D5
D6
Loadcell Tx
None Net/Gross
M/M reset
Tare
None
None
Suggested Digital Inputs for other applications
LCT + Pretare
None
Set Sps
M/M rese
None
None
LCT + PI
Stop LCT
None
M/M reset
Start PI
Man/auto
Beltweigher
None
Tot reset
M/M reset
None
None
Belt W + PI
Stop BW
Tot reset
M/M reset
StartPI
Man/Auto
Loss-in-Wght
Stop LiW
Tot reset
M/M reset
Start LiW
None
Loss in W+PI
Stop LiW
Tot reset
M/M reset
Start LiW
Start PI
Throughput
StopTP
Tot reset
Discharge
Start TP
Residule
Dynamometer None
M/M reset
Show kW
Show Nm
Show RPM
Bag Filler
Stop BW
Tot reset
RemoteTare Bagclamp
Psensor
FootSwitch
Batch Weigh
Stop BW
Intlok1
Intlok2
Intlok3
Intlok4
Start Batch
When the entire block is ready press Enter . This will set the whole block and move on to the next block, in
this case DISPLAYS.
Service Menu
Page
46