ADVANCED X10 PROGRAMMING OPTIONS
TimerLinc can be a member of up to 255 X10 scenes. An X10 scene address is just another X10
address, like the X10 Primary Address. When an X10 ON command is sent to an X10 scene address,
every X10 device with that X10 scene address will turn on to its independent On-Level at its independent
Ramp Rate (if a dimmable device). Sending an X10 OFF command to an X10 scene address will turn off
all devices that are members of that X10 scene, each at its independent Ramp Rate. Dimmable X10
devices will react to DIM and BRIGHT commands after the X10 scene address is sent. However, they will
ignore ALL ON and ALL OFF commands for the X10 scene address.
Remotely Setting an X10 Scene Address
1) Using an X10 controller, send the CLEAR sequence:
O16
N16
M16
P16
M16
2) Tap the Set button on TimerLinc to set the load to the desired state (on or off)
3) Send the following X10 address sequence:
M16
N16
O16
P16
4) Send the desired X10 scene address (house code and unit code)
Remotely Removing an X10 Scene Address
1) Using an X10 controller, send the CLEAR sequence:
O16
N16
M16
P16
M16
2) Send the TimerLinc‘s X10 Primary Address (house code and unit code)
3) Send an X10 ON or OFF command
4) Send the following X10 address sequence:
O16
P16
M16
N16
5) Send the X10 scene address you wish to remove (house code and unit code)