background image

Page 8 of 10 

2993-xx2 - Rev: 3/11/2014 9:21 AM 9:21:55 AM 

 

When you have identified the noise source, install a FilterLinc to isolate the noise source from the INSTEON 
network. 

Determining Source of Signaling Problems 

 

A problem area would be an outlet in which the tester has difficulty talking to the unit under test. 

 

Enable DISTANCE mode. 

 

Search the following list for your situation: 

o

 

No beeping and no On/Off of the device under test. 

 

Make sure device under test is linked as responder to Diagnostic Keypad. 

 

There may not be a signal path between Diagnostic Keypad and device under test. 

 

Confirm phases are coupled. 

 

Add dual-band INSTEON products if necessary. 

 

There may be noise at/near the device under test. 

 

Find and filter the noise-making device with a FilterLinc. 

o

 

No beeping, but the device under test goes on and off. 

 

The device under test is receiving the commands but the Diagnostic Keypad is not receiving 
the device’s positive acknowledgement that the command was received. 

 

Look for noise at the Diagnostic Keypad’s location. Move Diagnostic Keypad if necessary. 

o

 

Beeping, but the device under test doesn’t go on or off. 

 

Acknowledgement may be coming from a different unit. Link to intended device under test. 

 

Try moving Diagnostic Keypad to a different location and using ON/OFF TOGGLE to turn the 
device on and off. 

 

Confirm that the device was not linked at off. Turn the device on using its local switch, then 
press the ON/OFF TOGGLE button and verify if the device under test turns off but not on. If 
linked to off, relink Diagnostic Keypad with device under test set to on. 

o

 

The beeping on/off cadence is slower than other outlets. 

 

The path to the device under test is longer, but this may not be a problem. 

 

If the beep cadence is consistent, it’s likely not a problem. 

 

As you use the Diagnostic Keypad, you will be able to more easily recognize the beep 
patterns. 

o

 

The on/off beeping is spotty at best. 

 

The path to the device under test is poor. 

 

Add additional dual-band INSTEON devices to couple the phases. 

 

There may be noise in the path. Find and filter the noise-making device with a FilterLinc. 

Specifications 

General 

Product name 

INSTEON Diagnostic Keypad 

Brand / manufacturer 

INSTEON 

Manufacturer product number 

US: 2993-222 

EU: 2993-422 

UPC 

813922012699 

FCC ID 

SBP23342 

Industry Canada 

5202A-23342 

Warranty 

2 years, limited 

INSTEON 

INSTEON powerline mesh repeater 

Yes 

INSTEON RF mesh repeater 

N/A, powerline only 

INSTEON controller 

Yes 

Summary of Contents for 2993-222

Page 1: ...Page 1 of 10 2993 xx2 Rev 3 11 2014 9 21 AM 9 21 55 AM INSTEON Diagnostic Keypad Owner s Manual 2993 xx2 ...

Page 2: ...ORT Mode 5 TRAFFIC Corruption and Noise Monitor 5 DISTANCE Mode 6 LOCK UNLOCK 6 RELINK 7 UNLINK 7 Common Problem Solving Techniques 7 Testing RF Only Devices for Access Point Dual Band Device Placement 7 Locating Noise Problems 7 Determining Source of Signaling Problems 8 Specifications 8 Certification and Warranty 10 Certification 10 ETL UL Warning Safety Warning 10 Limited Warranty 10 Limitation...

Page 3: ... phase Attempting to use this product on non approved power lines may have hazardous consequences Use only indoors In the Box Tools Needed INSTEON Diagnostic Keypad INSTEON controllers to be tested Tabletop Enclosure Manual Features This INSTEON Diagnostic Keypad can be used to Find and diagnose signaling issues Test the signaling quality of an installation Stress the house by running a distance t...

Page 4: ...st device will still contain a half link to Diagnostic Keypad The first device will have to be factory reset to remove the half link UNLINK device upon completion of test Otherwise the device under test will retain a responder link ON OFF TOGGLE Sends on off broadcast without confirmations to unit under test BEEP Sends a beep message to unit under test some responders will still beep even after un...

Page 5: ...ginning of scene message Keypad will double beep upon receipt of success report with no errors Keypad will long beep upon receipt of success report with errors The success report feature was released in devices shipped after March 2012 A small number of INSTEON devices do not support this feature The delay between the beep and double beep will vary depending on the number of responders in the scen...

Page 6: ... DISTANCE button until LED is off 8 If testing the unit under test is complete UNLINK device LOCK UNLOCK This button allows you to disable or re enable local setup of unit under test This feature is in all products shipped after March 2012 LOCK UNLOCK prevents accidental changes being made to on level ramp rates etc To determine whether local setup is enabled on a device press and hold its Set but...

Page 7: ...ommunications are consistent the Access Point dual band device is in a good location o If the communications are not consistent relocate either the RF only device or the Access Point dual band device and retest If you relocate the Access Point dual band device move Diagnostic Keypad with it Locating Noise Problems Enable TRAFFIC mode disable REPORT and DISTANCE Activate scenes from various locatio...

Page 8: ...or off Acknowledgement may be coming from a different unit Link to intended device under test Try moving Diagnostic Keypad to a different location and using ON OFF TOGGLE to turn the device on and off Confirm that the device was not linked at off Turn the device on using its local switch then press the ON OFF TOGGLE button and verify if the device under test turns off but not on If linked to off r...

Page 9: ... clamp connections N A Case color White Set button 1 Plastic UV stabilized polycarbonate Beeper Yes Beep on button press N A LED White Operating environment Indoors Operating temperature range 32 o to 104 o F Operating humidity range 0 85 relative humidity Electrical Voltage 2993 222 110VAC 10 2993 422 240VAC 10 Frequency 50 60Hz Load type s N A not a load controller Maximum load N A not a load co...

Page 10: ... an explanation of the defect or error The repair replacement or refund that is provided for above shall be the full extent of Seller s liability with respect to this product For repair or replacement during the warranty period call INSTEON at 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to INSTEON ATTN Receiv...

Reviews: