background image

Page 10 of 10 

2993-xx2 - Rev: 3/11/2014 9:21 AM 9:21:55 AM 

Certification and Warranty 

Certification 

This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark 
signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S. and Canadian device safety standards, that the 
manufacturing site has been audited, and that the manufacturer has agreed to a program of quarterly factory follow-up inspections to verify continued conformance.  

ETL/UL Warning (Safety Warning) 
CAUTION: 

To reduce the risk of overheating and possible damage to other equipment, do not install this device to control a receptacle, a motor-operated appliance, a 

fluorescent lighting fixture, or a transformer-supplied appliance.  
Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas 
installer pour commander une prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.  

Limited Warranty 

Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase,  this product will be free from defects in 
material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or 
errors caused by misuse or neglect. If the product is found to be defective in material or workmanship, or if the product does not perform as warranted above during the 
warranty period, Seller will either repair it, replace it, or refund the purchase price, at its option, upon receipt of the product at the address below, postage prepaid, with 
proof of the date of purchase and an explanation of the defect or error. The repair, replacement, or refund that is provided for above shall be the full extent of Seller’s 
liability with respect to this product. For repair or replacement during the warranty period, call INSTEON at 800-762-7845 with the Model # and Revision # of the device 
to receive an RMA# and send the product, along with all other required materials to:  

 
INSTEON 
ATTN: Receiving 
16542 Millikan Ave. 
Irvine, CA 92606-5027 

Limitations 

The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or implied, including any warranty or merchantability or fitness 
for a particular purpose. Any implied warranty, including any warranty of merchantability or fitness for a particular purpose, which may not be disclaimed or supplanted 
as provided above shall be limited to the two-year of the express warranty above. No other representation or claim of any nature by any person shall be binding upon 
Seller or modify the terms of the above warranty and disclaimer.  
Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical tampering. For optimal use, manually verify the device 
state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.  

In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from possession or use of this device, including without limitation 
damage to property and, to the extent permitted by law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states do 
not allow limitations on how long an implied warranty lasts and/or the exclusion or limitation of damages, in which case the above limitations and/or exclusions may not 
apply to you. You may also have other legal rights that may vary from state to state.  

U.S Patent No. 7,345,998, International patents pending (see www.insteon.com). 
© Copyright 2014 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845, www.insteon.com

 

 

Summary of Contents for 2993-222

Page 1: ...Page 1 of 10 2993 xx2 Rev 3 11 2014 9 21 AM 9 21 55 AM INSTEON Diagnostic Keypad Owner s Manual 2993 xx2 ...

Page 2: ...ORT Mode 5 TRAFFIC Corruption and Noise Monitor 5 DISTANCE Mode 6 LOCK UNLOCK 6 RELINK 7 UNLINK 7 Common Problem Solving Techniques 7 Testing RF Only Devices for Access Point Dual Band Device Placement 7 Locating Noise Problems 7 Determining Source of Signaling Problems 8 Specifications 8 Certification and Warranty 10 Certification 10 ETL UL Warning Safety Warning 10 Limited Warranty 10 Limitation...

Page 3: ... phase Attempting to use this product on non approved power lines may have hazardous consequences Use only indoors In the Box Tools Needed INSTEON Diagnostic Keypad INSTEON controllers to be tested Tabletop Enclosure Manual Features This INSTEON Diagnostic Keypad can be used to Find and diagnose signaling issues Test the signaling quality of an installation Stress the house by running a distance t...

Page 4: ...st device will still contain a half link to Diagnostic Keypad The first device will have to be factory reset to remove the half link UNLINK device upon completion of test Otherwise the device under test will retain a responder link ON OFF TOGGLE Sends on off broadcast without confirmations to unit under test BEEP Sends a beep message to unit under test some responders will still beep even after un...

Page 5: ...ginning of scene message Keypad will double beep upon receipt of success report with no errors Keypad will long beep upon receipt of success report with errors The success report feature was released in devices shipped after March 2012 A small number of INSTEON devices do not support this feature The delay between the beep and double beep will vary depending on the number of responders in the scen...

Page 6: ... DISTANCE button until LED is off 8 If testing the unit under test is complete UNLINK device LOCK UNLOCK This button allows you to disable or re enable local setup of unit under test This feature is in all products shipped after March 2012 LOCK UNLOCK prevents accidental changes being made to on level ramp rates etc To determine whether local setup is enabled on a device press and hold its Set but...

Page 7: ...ommunications are consistent the Access Point dual band device is in a good location o If the communications are not consistent relocate either the RF only device or the Access Point dual band device and retest If you relocate the Access Point dual band device move Diagnostic Keypad with it Locating Noise Problems Enable TRAFFIC mode disable REPORT and DISTANCE Activate scenes from various locatio...

Page 8: ...or off Acknowledgement may be coming from a different unit Link to intended device under test Try moving Diagnostic Keypad to a different location and using ON OFF TOGGLE to turn the device on and off Confirm that the device was not linked at off Turn the device on using its local switch then press the ON OFF TOGGLE button and verify if the device under test turns off but not on If linked to off r...

Page 9: ... clamp connections N A Case color White Set button 1 Plastic UV stabilized polycarbonate Beeper Yes Beep on button press N A LED White Operating environment Indoors Operating temperature range 32 o to 104 o F Operating humidity range 0 85 relative humidity Electrical Voltage 2993 222 110VAC 10 2993 422 240VAC 10 Frequency 50 60Hz Load type s N A not a load controller Maximum load N A not a load co...

Page 10: ... an explanation of the defect or error The repair replacement or refund that is provided for above shall be the full extent of Seller s liability with respect to this product For repair or replacement during the warranty period call INSTEON at 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to INSTEON ATTN Receiv...