background image

                                                                                                                                  Page 27 of 32                                                                                       Rev: 10/13/2015 9:13 AM 

 
 

Beep 

 

Software configurable 

Yes 

RF range 

Up to 150-Feet (50m) open air 

Phase bridge detect beacon 

No, RF only device 

Insteon device category 

0x05 (all frequencies) 

Insteon device subcategory 

2441TH (915 MHz)  

0x0B 

2732-422 (869 MHz) 

0x0F 

2732-522 (921 MHz) 

0x10 

2732-242 (915 MHz) 

0x13 

2732-442 (869 MHz) 

0x14 

2732-542 (921 MHz) 

0x15 

X10 
X10 address 

N/A 

X10 transmitter 

N/A 

X10 receiver 

N/A 

X10 status response 

N/A 

X10 resume dim 

N/A 

X10 minimum transmit level 

N/A 

X10 minimum receive level 

N/A 

X10 messages repeated 

N/A 

Mechanical 

Mounting 

Wall mount 

Wire Connections 
Conventional Thermostat 

Common 24V 
Power 24V 
Heat 1 
Heat 2 
Fan 
Cooling 1 
Cooling 2 

Wire Connections 
Heat Pumps 

Common 24V 

Power 24V 

O/B Reversing Valve 

Auxiliary Heat 

Fan 

Compressor Stage 1 

Compressor Stage 2 

Screw clamp connections 

Yes, 10 position  

Case color  

White 

Set button 

Plastic 

UV stabilized ABS 

Beeper 

Yes 

Summary of Contents for 2732-242

Page 1: ...Page 1 of 32 Rev 10 13 2015 9 13 AM Insteon Thermostat Owner s Manual 2441TH 2732 422 2732 522 2732 242 2732 442 2732 542 ...

Page 2: ... Needed 11 Installation 11 Wire Connections 12 Test Operation 15 Adding an Insteon Wireless Thermostat 15 Insteon Programming 17 Add Insteon Thermostat as an Insteon Controller 17 Removing Insteon Thermostat as an Insteon Controller 19 Add Insteon Thermostat as an Insteon Responder 20 Remove Insteon Thermostat as an Insteon Responder 20 User Setup Mode Overview 22 User Setup Mode 22 Temperature an...

Page 3: ...s energy and money by remotely controlling and automating your home s heating and AC Communicates wirelessly over radio frequency RF Can automatically remotely control Insteon devices when Insteon Thermostat reaches a specified temperature or humidity level or switches to A C or heat Reports changes in thermostat modes temperature humidity setpoints and fan to compatible automation controllers or ...

Page 4: ...is 4 from the current setting To change the default offset value you must use software such as HouseLinc TM 4 Hold overrides a preprogrammed mode to stay in the current settings mode 5 Fan cycles between Auto and Always On there is no indicator for Auto Fan 6 Master makes this device the master temperature controller when you have one or more zone thermostats Pressing and holding Master does not a...

Page 5: ...indicated by the return annotation The Time of Day annotation is not displayed in the other four modes Off Heat Cool or Auto Both Cool and Heat setpoints are shown Up Down arrows increase or decrease values by the same amount When the thermostat moves to the next time period the setpoints will be adjusted accordingly Note To adjust the gap between the setpoints in Auto mode press Mode to select He...

Page 6: ...nt based on the mode you are in From Off Mode Energy button does nothing because the system is off at maximum energy savings already When Energy appears on the screen for Auto Cool and Heat Modes the 4 setback is engaged From Heat Mode Heat setback as specified Default setback is 4 less Notice that Heating is active on the left but not on the right since the setpoint is lower that the actual tempe...

Page 7: ...rmostat from Insteon scenes It functions like the Set button on other Insteon devices Time Sensor Button Operations The Time Sensor button allows the user to set the current day and time It cycles among hour minute day and 12 24 hour format Up Down arrows cycle through the available options Go to the next Time Sensor step by pressing Time Sensor button again Exit Time Sensor setup by Timing out 4 ...

Page 8: ...n and Sleep Go to the next step by pressing Program again Exit Program setup by Timing out 4 minutes Pressing Mode button Note Colored text below indicate element that should be blinking during setting procedure First press of Program Selects from available pre program modes Up Down arrows cycle through Wake Leave Return and Sleep NOTE Energy is not a part of this option Once a preprogrammed mode ...

Page 9: ...start of one program mode is also the end of the previous program mode Fourth press of Program Cool setpoint Up Down arrows cycle through temperature Fifth press of Program Heat setpoint Up Down arrows cycle through temperature Sixth press of Program Restarts the process to program another Mode Day NOTE The four modes come preprogrammed The defaults are for all days Day Modes Start Time Thermostat...

Page 10: ... Operation First press and hold Makes the local Insteon Thermostat the master temperature controller To perform this press and hold Master button for 3 seconds Insteon Thermostat beeps once Release Note This is only valid if at least one Insteon Thermostat Zone Thermostat is linked to Insteon Thermostat Before pressing Master button Notice that the left remote sensor is currently the Master temper...

Page 11: ... observing that compressor fan do not come on 3 Turn off breaker fuse to furnace a If thermostat no longer functions move to next step b If thermostat still functions it is probably running off battery power Try to turn on heat i If heat doesn t turn on move to next step ii Otherwise turn off heat and wait until furnace fan stops then try another breaker until heat no longer runs 4 Remove cover fr...

Page 12: ...ws Wire color from furnace AC unit Wire colors may vary Function Install on Insteon Thermostat connector Black or blue Common 24V 24V COM Red Power 24V 24 RH White Heat 1 W1 Brown Heat 2 W2 Green Fan G Yellow Cooling 1 Y1 Light blue Cooling 2 Y2 Diagram below shows inside of Insteon Thermostat wall mount case 15 Insert C wire into terminal C and tighten using small screwdriver either flathead or P...

Page 13: ...which mode to operate making heat or cooling when the compressor is activated Most residential heat pumps operate in the O mode where the thermostat will energize the valve during cooling By default the Insteon Thermostat is set to O mode Commercial systems and many models made by Rheem and Rudd operate in the B mode where the reversing value is energized during heating If your system is making he...

Page 14: ...Page 14 of 32 Rev 10 13 2015 9 13 AM 4 Press the UP or DOWN button to change between O and B modes 5 Press PROGRAM to exit ...

Page 15: ...w once to increase both Heat and Cool setpoints by 1 4 Tap Down arrow once to decrease both Heat and Cool setpoints by 1 5 Tap Mode once to enter Time of Day mode Indicated by Auto at bottom and relevant time of day Wake Leave Return Sleep to right of Heat Cool set temps 6 Tap Mode once more to return to Off mode Additional Modes for Insteon Thermostat for Heat Pumps Emergency or Supplemental Heat...

Page 16: ... Thermostat will be displayed in position 1 as the small temperature segments at top center of the display A visual inspection of each display will reveal the Master status of each Insteon Thermostat or Zone Thermostat Note Only the Insteon Thermostat is directly connected to the HVAC system via wires If you plan on operating multiple Insteon Wireless Thermostats you must have at least one Insteon...

Page 17: ...ice only they are not shared or matched among thermostats 1 Press and hold Insteon Thermostat s Set button until it beeps Insteon Thermostat will beep Insteon Thermostat Set LED will blink green 2 Tap Up or Down arrows to select from Groups 1 4 to add to a scene Group 1 Cooling mode change default Group 2 Heating mode change Group 3 Dehumidification high humidity setpoint Group 4 Humidification lo...

Page 18: ...Page 18 of 32 Rev 10 13 2015 9 13 AM LCD display after 2 seconds LCD display when using Up or Down arrows to select from the 4 controller groups ...

Page 19: ...on Thermostat Set LED will blink green Insteon Thermostat will beep 2 Press and hold Insteon Thermostat s Set button again to put it in scene mode Insteon Thermostat Set LED will blink red Insteon Thermostat will beep LCD display indicates the group from which you are removing the scene 3 Tap Up and Down arrows to select appropriate group to remove from Group 1 Cooling mode change default Group 2 ...

Page 20: ...in linking mode press and hold controller Set button 3 Simultaneously press and hold Insteon Thermostat s Set button and Down arrow Insteon Thermostat Set LED will blink green and unit will beep Insteon Thermostat will double beep LED will return to previous state Display while in Add to a Scene Mode to ON or OFF Remove Insteon Thermostat as an Insteon Responder If you want to remove Insteon Therm...

Page 21: ...nsteon Thermostat will no longer respond Removing a scene from an incoming OFF command 1 Press and hold controller s scene button until controller beeps Controller s LED will blink 2 Press and hold controller s scene button until controller beeps again Controller s LED will continue blinking 3 Simultaneously press and hold Insteon Thermostat s Set button and Down arrow Insteon Thermostat Set LED w...

Page 22: ...ore to enter the User Setup Mode User Setup Mode 1 Press and hold Program button to access the following options Press Mode to step between menu items sub mode number will appear on top of the screen o Sub mode 01 Display LED on time select default is 10 seconds o Sub mode 02 Humidity low setpoint default is 30 ...

Page 23: ...n arrow to step between Off 10 sec 60 sec and On b Use HouseLinc software to set the LED backlight ON time in 1 second intervals Sub mode 02 Humidity low setpoint humidification 30 default a Up arrow Increase humidity setpoint b Down arrow Decrease humidity setpoint c Range 0 to 79 Sub mode 03 Humidity high setpoint dehumidification 90 default a Up arrow Increase humidity setpoint b Down arrow Dec...

Page 24: ...en adjusting Insteon Thermostat 1 Press and hold the Program button tap Time Sensor to enter Temperature Calibration Mode 2 Tap Mode to step between temperature calibration and humidity calibration Temperature Calibration The top left number 77 in example is the current reading according to the temperature sensor The top right number 14 in example is the current offset represents 1 4 These numbers...

Page 25: ...Thermostat s setpoint is set at 5 F or C or more below ambient in Cool mode and 5 F or C or more above ambient in Heat mode Heat mode setpoint is 80 ambient is 72 first and second stage engaged Cool mode setpoint is 78 ambient is 84 first and second stage engaged Insteon Thermostat has been active in Heat or Cool for longer than 10 minutes and did not reach setpoint Heat mode ran for 10 minutes an...

Page 26: ... seconds Insteon Thermostat will perform a series of self tests then return to normal operations Insteon Thermostat display will return to normal Specifications General Product name Insteon Thermostat Brand manufacturer Insteon Manufacturer product number 2441TH US 2732 422 EU 2732 522 AUS NZ UPC 813922 010824 US Can 813922 012859 EU 813922 012866 AUS NZ Warranty 2 years limited Insteon Insteon po...

Page 27: ...5 X10 X10 address N A X10 transmitter N A X10 receiver N A X10 status response N A X10 resume dim N A X10 minimum transmit level N A X10 minimum receive level N A X10 messages repeated N A Mechanical Mounting Wall mount Wire Connections Conventional Thermostat Common 24V Power 24V Heat 1 Heat 2 Fan Cooling 1 Cooling 2 Wire Connections Heat Pumps Common 24V Power 24V O B Reversing Valve Auxiliary H...

Page 28: ...52 10mA LED Backlight on transmitting Insteon commands to other devices Standby power consumption 0 7 Watts 26 92mA LED backlight off not receiving or transmitting Insteon commands Certifications FCC ID Pat 15B 15C and IC RSS 210 Issue 8 US Can ETSI EN 300 220 1 220 2 ETSI EN 301 489 1 489 3 Eu AS NZ 4268 C Tick N16509 FCC I D SBP2441T Marks WEEE RoHS All models C Tick N16509 Aus NZ model Safety a...

Page 29: ...ew one but now SmartLinc and Insteon app don t recognize it SmartLinc and the Insteon app communicate via Insteon I D s They are still trying to communicate to the old thermostat s I D Update the Insteon I D on both SmartLinc and the Insteon app with your new thermostat s I D I ve set my thermostat to Off but my furnace or AC unit continues to run for several minutes Insteon Thermostat for Heat Pu...

Page 30: ...ctric and electronic equipment via designated collection facilities appointed by the government or local authorities Correct disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased th...

Page 31: ...orwegian Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU direktiv 1999 5 EF Suomi Finnish Tämä laite tÿttää direktiivin 1999 5 EY olennaiset vaatimukset ja on siinä asetettujen muiden laitetta koskevien määräysten mukainen Dansk Danish Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Direktiv 1999 5 EF Polski Pol...

Page 32: ... the product in this Owner s Manual This warranty shall not apply to defects or errors caused by misuse or neglect If the product is found to be defective in material or workmanship or if the product does not perform as warranted above during the warranty period Seller will either repair it replace it or refund the purchase price at its option upon receipt of the product at the address below posta...