Frequency 

50/60Hz auto detected at power-up 

Maximum load 

16A – 240VAC (EUR) 
10A – 240VAC (AUS/NZ) 
3600W/240VAC Resistive 
700W/240VAC Inductive/Capacitive 
2000W/240VAC Bulbs/Low Voltage Halogen 

Minimum load 

N/A 

Load type(s) 

Resistive 
Inductive/capacitive 
Low voltage halogen 

Hardwired remote control 

N/A 

Retains all settings without power 

Yes, saved in non-volatile EEPROM 

Standby power consumption 

< 0.75 watts 

Safety approved 

CE, C-Tick 

Certifications 

EN 300 220-2, 301 489-3 
AS/NZS 4268, CISPR 22 
IEC 60669-2-1 

All product specifications are subject to change. 

Troubleshooting 

Problem 

Possible Cause 

Solution 

On/Off Module LED is not turning 

on 

On/Off Module is not 

getting power  

Make sure On/Off Module is not 

plugged into a switched outlet that is 

turned off 

On/Off Module won’t add to a 

scene as a controller or responder  

On/Off Module or the 

controller is plugged into a 

power strip or AC line filter 

Powerline signals can’t travel through 

some power filters. Plug On/Off 

Module or controller into an 

unswitched wall outlet. 

The INSTEON signal may 

be too weak 

Add additional INSTEON devices or 

move around existing INSTEON 

devices. All INSTEON devices act as 

INSTEON network repeaters.  

Large appliances, such as 

refrigerators or air 

conditioners, may be 

producing electrical noise 

on the powerline. 

Summary of Contents for 2633-422

Page 1: ...Page 1 of 14 Rev 1 8 2013 7 36 PM On Off Module Owner s Manual 2633 422 France 2633 432 Germany 2633 442 UK 2633 522 AUS NZ 2633 442 UK 2633 522 Aus NZ 2633 422 France 2633 432 Germany...

Page 2: ...onders 7 Remove On Off Module as a Controller 7 Remove On Off Module as a Responder 7 Remove On Off Module as a Controller of Multiple Responders 8 Factory Reset 8 X10 Setup 8 Add X10 Address 8 Remove...

Page 3: ...product is assigned a unique INSTEON I D which is printed on the product s label To reduce the risk of overheating and possible damage to other equipment do not use this product to control loads in ex...

Page 4: ...linking red 3 Press and hold On Off Module set button until it beeps a third time LED will start blinking green 4 Tap On Off Module set button once LED starts double blinking green 5 Press and hold On...

Page 5: ...installation using the switch connected to the module or remotely via software sold separately All On Off Module settings can be managed remotely via software sold separately Make On Off Module a Res...

Page 6: ...f a group is a 3 way lighting circuit 2 switches For simplicity we will assume that the desired group level is on The following steps will create a virtual 3 way circuit including device A and device...

Page 7: ...u no longer want On Off Module to control another device or are removing On Off Module from your network it is important that you follow the instructions below for each responder 1 Press and hold On O...

Page 8: ...e LED will start blinking red 3 Press and hold On Off Module set button until it beeps a third time LED will start blinking green 4 Slowly tap On Off Module set button 3 times LED will start double bl...

Page 9: ...N INSTEON powerline mesh repeater Yes INSTEON RF mesh repeater Yes INSTEON controller Yes INSTEON responder Yes Maximum links scenes 400 LED Green when load is on red when load is off Blinks green onc...

Page 10: ...ed X10 minimum transmit level 3 2 Vpp into 5 Ohms X10 minimum receive level 20mV into 5 Ohms X10 messages repeated No Mechanical Mounting AC outlet Wires N A Screw clamp connections N A Case color Whi...

Page 11: ...s are subject to change Troubleshooting Problem Possible Cause Solution On Off Module LED is not turning on On Off Module is not getting power Make sure On Off Module is not plugged into a switched ou...

Page 12: ...Module See Factory Reset On Off Module can turn off a responder but nothing happens when I send an on command from On Off Module The responder may be added to the scene at its off state Add the devic...

Page 13: ...practical or add an additional dual band device RF Range Test If LED is blinking Device is within RF communication range If LED is not blinking Device is not within RF communication range Relocate if...

Page 14: ...equipment can be reused as new material saving the use of virgin raw materials and energy of producing these Separate collection and treatment of WEEE will thus decrease CO2 emissions as well For the...

Reviews: