b) Series III Specifications
Seismic
Range
10 in/s (254 mm/s).
Resolution
0.005 in/s (0.127 mm/s), to 0.000625 in/s (0.0159 mm/s) with built–in preamp.
Trigger Levels
0.005 to 10 in/s (0.127 to 254 mm/s) in steps of 0.001 in/s (0.01 mm).
Frequency Analysis
National and Local Standards for all countries (see text).
Accuracy
3% at 15 Hz.
Acceleration,
Displacement
Calculated using entire waveform, not estimated at peak.
Air Linear
Range
88–148 dB, 7.25 x 10
-5
psi to 0.0725 psi, 0.5 Pa to 500 Pa.
Resolution
0.1 dB above 120 dB (0.25 Pa).
Trigger Levels
100–148 dB in 1 dB steps.
Accuracy
0.2 dB at 30 Hertz and 127 dB.
“A” Weight (optional)
Range
50 to 110 dB in steps of 0.1 dB. (Impulse Response
−
35 milliseconds)
Sampling Rate
Standard 1024 samples per second per channel to 16,384 (8,192 for 8 channel).
Event Storage
Full Waveform Events
300 standard and 1500 optional at standard sample rate of 1024.
Summary Events
1750 standard and 8750 optional at standard sample rates of 1024.
Frequency Response
2 to 300 Hz
Ground and Air, Independent of record time.
Full Waveform Recording
Fixed Record Modes
Manual, single shot, continuous and programmed start/stop.
Fixed Record Time
1 to 100, 300 or 500 sec plus 0.25 sec pre-trigger.
Auto Record Mode
1 to 100, 300 or 500 sec plus 0.25 sec pre-trigger.
Strip Chart Recording
Record Method
Record to memory and/or internal printer. Program interval 2, 5, 15, 60, 300 or 900 sec.
Days Storage
2.8 or 14 days at 5 second interval. 34 or 170 days at 60 second interval.
Histogram Record Method
Record to memory and/or internal printer. Program interval 2, 5, 15, 60, 300 or 900 sec.
Histogram Days Storage
2.4 or 12 days at 5 second interval. 29 or 147 days at 60 second interval.
Waveform Events
Up to 13 one-second events (1024 sample rate, four channels recording).
Histogram Combo Mode
Waveform Record Times
1 to 13 seconds plus 0.25 sec pre-trigger.
Special Functions
Timer Operation
Programmed start/stop.
Self Check
Programmable daily check.
Scaled Distance
Weight and distance stored with event.
Monitor Log
History printout programmable up to all events stored.
Automatic download
Automatic downloading of data from a unattended monitor with Auto Call
Home.
Measurement Units
Imperial or metric, dB or linear air pressure, or in units of custom sensors.
Printer
Resolution
576 dots/line and 0.0049 inches (0.125 mm) per dot.
Print Time
Less than 10 seconds for typical 1 second event with full analysis.
Paper Control
Paper tear slot or automatic paper takeup, separate keys for feed and takeup.
Rated Life – print head
18 miles (30 km) of printing.
Number of Copies
1 to 10 copies automatic, any number manual.
User interface
Keyboard
64 domed tactile with separate keys for common functions.
Display
4 line by 20 character high contrast backlit display with on line help.
Battery Life
30 days continuous recording, 70 days with timer, printing will decrease life.
Fuse
5 A/250 V
Summary of Contents for Blastmate III
Page 1: ......
Page 6: ...iv BlastMate III Operator Manual Notes ...
Page 20: ...Chapter 2 2 6 BlastMate III Operator Manual Notes ...
Page 50: ......
Page 74: ...Chapter 6 6 6 BlastMate III Operator Manual Notes ...
Page 77: ...Appendix BlastMate III Operator Manual A 1 Appendix ...
Page 78: ...Appendix A 2 BlastMate III Operator Manual ...
Page 84: ...Appendix A 8 BlastMate III Operator Manual Notes ...
Page 90: ...Index I 6 BlastMate III Operator Manual Notes ...