background image

1

Installation instructions & user guide

 

T210042 InstaTap office manual v1.01 June 2022

Instanta 

 

InstaTap

Installation and user instructions

Under-Counter, Push-Button Dispensers for the office
Boiling Chilled I2BC520, all models
Boiling I2B5, all models

Summary of Contents for InstaTap

Page 1: ...ns user guide T210042 InstaTap office manual v1 01 June 2022 Instanta InstaTap Installation and user instructions Under Counter Push Button Dispensers for the office Boiling Chilled I2BC520 all models...

Page 2: ...6 4 General in cupboard arrangement Boiling chilled models 12 6 5 Push fit best practice 13 6 6 Connect the water supply 14 6 7 Water block 16 6 8 Manifold connections and controls 17 6 9 Connect the...

Page 3: ...on of symbols Read the instructions WARNING Danger of electric shock Hot surface U V Highly flammable Explanation of acronyms UCB Under counter boiler UCC Under counter chiller 9 1 4 Set the temperatu...

Page 4: ...LAMMABLE R290 refrigerant under pressure Check the rating plate or contact Instanta before commencing work Maintenance of the refrigeration unit must be carried out by an accredited service provider o...

Page 5: ...cord The resistance of the earth connection to each exposed metal part must be less than 1 Use the power cable supplied It is the responsibility of the installer to ensure the power point is earthed A...

Page 6: ...oning the under counter appliances ensure power supply cords are not trapped or damaged If damaged they must be replaced by an Instanta service provider or a qualified electrician Instanta cannot be h...

Page 7: ...us on 0345 6 005 005 to book a commissioning service If your InstaTap is left idle before use for water taste and quality reasons any non use of more than 48 hours we recommend a system flush be perfo...

Page 8: ...ter boiler Capacity L N A 5 Dimensions W x D x H mm 180 x 340 x 390 230 x 415 x 510 Supply voltage V 230 50Hz AC 230 50Hz AC Power rating kW 0 185 2 25 Mains water supply pressure bar 2 5 2 5 Fill typ...

Page 9: ...equal Tee 3 2 3 8 push fit G3 4 brass connector 1 1 Install rail water block 3 2 1m 3 8 JG pipe 1 UBC UCC interconnect cable Under counter chiller ventilation kit 1 Air inlet grille retaining screws 1...

Page 10: ...ler UCC Use instructions supplied with individual kit parts Use of tools can be hazardous assess the risks before you start 6 1 Positioning and ventilation all models Adequate ventilation must be prov...

Page 11: ...h this section of the manual 12 11 9 2 5 10 13 3 Mains water supply 1 Isolation valve install rail inc non return valve 2 Water block 3 4 UCB Mains electricity supply 5 Font waste pipe 6 Waste to drai...

Page 12: ...of the manual BC office Under counter boiler UCB 1 2 UCB Mains electricity supply 5 UCB control cable 3 UCB mains water connection 4 UCB Boiling water tube Water filter 12 2 5 15 1 3 6 17 16 14 12 13...

Page 13: ...er guide T210042 InstaTap office manual v1 01 June 2022 2 Pull pipe out 1 Press collet down Insert Remove 2 Push pipe to end stop 1 Cut pipe clean square 6 5 Push fit best practice SECTION 6 Installin...

Page 14: ...ponsible for any appliance malfunction if the water pressure is not within the range stated If in doubt consult your water supply company Connect to a wholesome cat 1 cold drinking water supply using...

Page 15: ...manual v1 01 June 2022 SECTION 6 Installing the under counter appliances 15mm mains water connection Isolation valve Water block 2x 3 4 3 8 adaptor 3 8 flexible pipe Appliance water connections Insta...

Page 16: ...connected via the 3 4 3 8 push fit brass fitting supplied Ensure that the direction of flow through the Water Block is correct and that the filter screen see Fig 2 is inserted correctly with the conve...

Page 17: ...the system together CONTROL CABLE CHILLED OUT FLOW CONTROL MAINS WATER MAINS ELECTRICITY P U S H L O C K HOT WATER OUT VENT FONT CONTROL CHILLER UCB top view UCC top view Blue pipe White tube Red tub...

Page 18: ...e mains plug to a 230V 50Hz 13A socket Before you start read Section 2 Important safety instructions Section 3 Warnings Regulatory information Do not switch on the mains electricity supply until insta...

Page 19: ...arth pin of the mains plug Insulation resistance meter or DMM Before installation the earth continuity of both the UCB UCC must be checked Use an insulation tester appliance tester DMM or continuity t...

Page 20: ...on the screen The tank fills NOT READY FILLING O C is displayed If the tank does not fill to its pre set level within 6 minutes CHECK WATER is displayed If this happens check that the isolation valve...

Page 21: ...illumination is extinguished The tap controls illuminate The UCB does not fill completely at once The water input is electronically controlled to obtain maximum output temperature and efficiency Disp...

Page 22: ...ck Set cup size boiling auto dispense Boiling manual dispense The exclamation mark on tap flashes when in fault mode at the same time warning triangle flashes on appliance display screen Boiling Boili...

Page 23: ...ot need to be disabled when dispensing chilled water Safety lock is illuminated When the safety lock is enabled Exclamation mark is extinguished To disable the safety lock Press safety lock All icons...

Page 24: ...To manually dispense boiling water place cup on font Press the safety lock 8 3 Dispense boiling water from the UCB NOT READY o C HEATING NOT READY o C HEATING 70 o C SOFT MEDIUM HARD CHANGE FILTER Pr...

Page 25: ...icon to dispense 8 5 Adjust the chilled water flow rate from the UCC The chilled water flow rate has been factory set however on site adjustment may be necessary The water flow rate adjustment knob i...

Page 26: ...change from on demand dispense default to set volume dispense Switch off under counter boiler UCB using ON OFF button Switch OFF mains power supply and wait 10 seconds Switch back ON and at the same...

Page 27: ...sanitary cap from the new filter do not touch the connector Moisten the new filter connector with clean tap water Insert the new filter see above Flush the filter see page 28 Reset the filter monitor...

Page 28: ...ve on the install rail Flush the new filter with the volume of water stated in the instructions supplied with the filter usually a minimum of 10 litres Turn ON the water supply to the under counter ap...

Page 29: ...played Press ON OFF button incrementally to adjust the temperature by 1o C per increment The adjustment will increase the temperature to set a lower temperature continue to cycle through the range 9 1...

Page 30: ...plied in your area consult your local water authority or call Technical Support on 0345 6 005 005 Continuing on from the temperature setting screen Press hold ON OFF button long push for approximately...

Page 31: ...a sanitising wipe and leave to air dry Cleaning of the tap and dispensing outlets must only be undertaken with alcohol or sanitising wipes Chemicals should NOT be sprayed onto the Tap or UCB UCC at a...

Page 32: ...level sensors NOT READY OF Red screen flashing with warning triangles Over boiled due to excessive lime scale in tank Faulty Element Thermistor disconnected wires cut or faulty Boil dry safety switch...

Page 33: ...manual v1 01 June 2022 Before calling for service switch the appliance off at the mains supply and then switch back on after 10 minutes If the fault does not clear call technical support for advice o...

Page 34: ...ntries laws and regulations your product and or its battery shall be disposed of separately from household waste When this product reaches its end of life take it to a collection point designated by l...

Page 35: ...and component failure with the following exclusions Problems caused by hard water and limescale We regret that we cannot be held responsible for problems caused by hard water Accidental damage misuse...

Page 36: ...tallation instructions user guide T210042 InstaTap office manual v1 01 June 2022 www zipwaterco uk www instanta com Zip Water UK Instanta Trafalgar House Rash s Green Dereham Norfolk NR19 1JG 0345 6 0...

Reviews: