37
Item
Description
‐
1 × BMC management network port
OS installation on the USB mobile storage media is not recommended.
Fan
12 × 6056 Fan
System
Management
Provides a dedicated Ethernet management port, which supports
remote control, SMTP, KVM, management via SNMP, and virtual
media
Power
Supply
Four 1600/2000/2200/3000 W Platinum level PSUs in 2+2
redundancy
6.2
Environmental Specifications
Table 6-2 Environmental Specifications
Parameter
Description
Temperature
(1, 2, 3)
Operating: 5°C to 35°C (41°F to 95°F)
Storage (packed): -40°C to +70°C (-40°F to +158°F)
Storage (unpacked): -40°C to +55°C (-40°F to
+131°F)
Relative Humidity (RH,
non-condensing)
Operating: 10% - 90% RH
Storage (packed): 10% - 93% RH
Storage (unpacked): 10% - 93% RH
Operating Altitude
≤ 3050 m (10000 ft)
0 - 950 m (0 – 3,117 ft): The maximum allowable
ambient temperature is 35°C (95°F)
950 – 3,050 m (3,117 – 10,000 ft): The maximum
allowable ambient temperature decreases by 1°C
per 300 m (1°F per 546 ft)
Corrosive Gaseous
Contaminants
Maximum growth rate of corrosion film thickness:
Copper coupon: 300 Å/month (compliant with
the gaseous corrosivity level of G1 defined in
ANSI/ISA-71.04-2013)