![Inspur NE5260M5 User Manual Download Page 14](http://html.mh-extra.com/html/inspur/ne5260m5/ne5260m5_user-manual_2069382014.webp)
8
PCI Expansion Slot
2 onboard PCI Express 3.0 x32 slots, used to support PCI-E Riser cards.
The Riser card supports horizontal-inserted full-height cards.
Full configuration 1:
One Riser card can be installed into the Riser slot1 (CPU0).
Supports 1 PCI Express 3.0 x16 slot (top slot, FHFL card) + 1 PCI Express 3.0
x16 slot (middle slot, x8 lanes, FHHL card) + 1 PCI Express3.0 x8 slot (bottom
slot, FHHL card).
One Riser card can be installed into the Riser slot2 (CPU1).
Supports 1 PCI Express 3.0 x16 slot (top slot, FH ¾ L card) + 1 PCI Express 3.0
x16 slot (middle slot, x8 lanes, FHHL card) + 1 PCI Express3.0 x8 slot (bottom
slot, FHHL card).
Full configuration 2:
One Riser card can be installed into the Riser slot1 (CPU0).
Supports 2 PCI Express 3.0 x16 slots (top slot supports dual-width FHFL card,
and bottom slot supports FHHL card).
One Riser card can be installed into the Riser slot2 (CPU1).
Supports 2 PCI Express 3.0 x16 slots (top slot supports dual-width FHFL card,
and bottom slot supports FHHL card).
Drive
Drive Type
Only supports drives installed in the front of the server.
Supports up to 6 2.5-inch SAS/SATA /NVME drives at the same time;
Or 4 2.5-inch NVME 2 2.5-inch SATA drives;
Or 2 2.5-inch NVME 4 2.5-inch SATA drives;
Or 4 2.5-inch NVME drives (QAT configuration can support NUMA Balancing).
(It depends on the configuration of machine you purchased.)
Supports dual M.2 SSDs.
Power
Specifications
Supports dual platinum AC PSUs of 550W/800W/1300W/1600W/2000W
output power; supports -48V DC PSU; 1+1 redundancy; 2 power modules;
supports PMBus PSU; Node Manager 4.0 function
Power Input
Please refer to the power input on the nameplate label of the host.
Physical
Packing Box Dimensions
673 width × 348 height × 601 depth (unit: mm)
Host Machine Dimensions 448 width × 87.5 height × 430 depth (unit: mm)
Product Weight
Full configuration
Gross weight: 28kg (Gross weight includes: Host + Packing Box + Rails +
Accessory Box)
Environmental
Operating Temperature
0
℃
-45
℃
(It depends on the configuration of machine you purchased.)
Storage & Transportation
Temperature
-40
℃
-70
℃
Operating Humidity
10
%
-85
%
relative humidity
Storage & Transportation
Humidity
10
%
-93
%
relative humidity
Summary of Contents for NE5260M5
Page 1: ...Inspur Server User Manual NE5260M5 ...
Page 21: ...15 Operations 3 Remove the access panel 4 Remove the air baffle ...
Page 34: ...28 7 Cabling 1 Data cables of the power board 2 Data cables of the drive backplane 2 1 6NVME ...
Page 35: ...29 Cabling 2 2 6SATA 2 3 4NVME ...
Page 36: ...30 2 4 4NVME 2SATA 2 5 2NVME 4SATA ...
Page 107: ...BMC Settings 101 ...
Page 109: ...BMC Settings 103 ...
Page 110: ...104 ...
Page 111: ...BMC Settings 105 ...
Page 113: ...BMC Settings 107 ...
Page 116: ...110 ...