Common Faults, Diagnosis and Troubleshooting
119
service.
3)
Power module LEDis off or red
Description:
The server is under normal operation, but a certain power module LED is off or red.
Suggestions:
a.
Firstly check whether all power cables are normal, and plug in the power cables again.
b.
If the fault still exists, insert the power module again.
c.
If shutdown is allowed, you could exchange the two power modules to judge whether it is
a power module fault.
d.
If above operations could not resolve the problem, please contact Inspur customer service.
4)
HDD status LED is abnormal
Description:
The server is under normal operation, but the HDD status LED is off or red.
Suggestions:
a.
If it is caused by manual operations, restore the array through RAID configuration.
b.
If there are no manual operations, check whether the HDDs are identified normally. If the
server is configured with an RAID card, login to the RAID management interface to check
whether there is an HDD failure.
c.
If there is an HDD failure, or the above operations could not resolve the problem, please
contact Inspur customer service.
Note:
Hot-plugging HDD allows users to take out or replace the HDD without system
shutdown and power off, which improves the system disaster recovery capability, scalability
and flexibility. It only means the hot-plug HDD can be plugged in and out online without
damage, and the following two items need to be noticed:① Depending on the RAID level,
hot plugging the HDD in the RAID will cause RAID degradation or failure. When installing
a new HDD, different RAID cards have different policies, you may need to login to the
RAID card management interface for recovery. ② Remove the HDD until the HDD motor
stops completely, to prevent damage to the motor. For the operations on the RAID card
management interface, please refer to Inspur technical website: www.4008600011.com.
5)
Chassis fans make excessive noise
Suggestions:
a.
Firstly check whether the chassis fans operate at a high speed caused by the over-
temperature chassis.
Summary of Contents for NE5260M5
Page 1: ...Inspur Server User Manual NE5260M5 ...
Page 21: ...15 Operations 3 Remove the access panel 4 Remove the air baffle ...
Page 34: ...28 7 Cabling 1 Data cables of the power board 2 Data cables of the drive backplane 2 1 6NVME ...
Page 35: ...29 Cabling 2 2 6SATA 2 3 4NVME ...
Page 36: ...30 2 4 4NVME 2SATA 2 5 2NVME 4SATA ...
Page 107: ...BMC Settings 101 ...
Page 109: ...BMC Settings 103 ...
Page 110: ...104 ...
Page 111: ...BMC Settings 105 ...
Page 113: ...BMC Settings 107 ...
Page 116: ...110 ...