64
Figure 3-60 Setting Operation to Unassign Hot Spare Drive
b.
Select
Go
and press <Enter> to enter the operation confirmation screen.
c.
Set
Confirm
to
Enabled.
d.
Select
Yes
and press <Enter>.
The operation has been performed
successfully
appears.
e.
Press <Enter> to complete the configuration and return to the previous
screen.
3.4.4
Deleting RAID Arrays
Method 1:
Procedures:
1.
Log in to the management screen.
2.
Enter Virtual Drive Management screen.
a.
Select
Main Menu
on the main screen and press <Enter>.
b.
Select
Virtual Drive Management
and press <Enter>.