31
Parameter
Description
Drive cache
Physical drive cache policy, including:
Unchanged
: The current drive cache policy is not
changed.
Enable
: During data read/write, data is cached through
drives, which improves the write performance. However,
data will be lost in case of power outage if no protection
mechanism is available.
Disable
: During data read/write, data is not cached
through drives. Data will not be lost in case of power
outage.
Default
Initialization
Indicates the default initialization mode, including:
No
: Does not perform initialization.
Fast
: Performs fast initialization.
Full
: Performs full initialization.
Emulation Type
Logical sectors reported in OS.
If the drives in a RAID array are 512 B/512 B:
Default
: The logical sectors are 512 B/512 B.
None
: The logical sectors are 512 B/512 B.
Force
: The logical sectors are 512 B/4 KB.
If the drives in a RAID array are 512 B/4 KB:
Default
: The logical sectors are 512 B/4 KB.
None
: The logical sectors are 512 B/512 B.
Force
: The logical sectors are 512 B/4 KB.
Save
Configuration
Saves the current configurations.
9.
On the popup screen, set
Confirm
to
Enabled
and select
Yes
, and then press
<Enter>.
Summary of Contents for 3408 Series
Page 62: ...57 Figure 3 52 Selecting the Drive to be Configured Figure 3 53 Operation Screen ...
Page 78: ...73 Figure 3 73 Setting Choose Profile to 13_PD64 NVMe4 ...
Page 85: ...80 Figure 4 8 Selecting Load Driver 11 On the screen shown click Browse and press Enter ...
Page 86: ...81 Figure 4 9 Clicking Browse To install the driver 1 Select GHOST C as shown below ...
Page 89: ...84 Figure 4 12 Loading the Driver 4 On the screen shown click Next ...