Inspire Home Automation
www.inspirehomeautomation.co.uk
[email protected]
01202 798390
8
You should have the following.
Allow a minute for the Relay Module to connect to the Gateway after they have both been powered up.
If after this time, the Relay Module does not have a valid connection, you will see all three lights on the
Relay Module rapidly flash Orange every 10 seconds.
If there is no RF link displayed on the Thermostat, and it was switched on before the Gateway, it may
take up to 10 minutes to link up. To avoid waiting, ensure the Gateway is plugged in, then reset the
Thermostat by pressing and holding all four buttons for 5 seconds. The unit should reset and connect
within 30 seconds.
Testing the Hot Water
HW. The light should be out. Press the HW button twice to switch it on.
It will light green and the unit will call for heat on the HW circuit. Check that the boiler has fired up and
any zone valves have moved to their appropriate positions. Press the button again to turn the channel off.
Testing the Central Heating
The CH light should be green. On the Thermostat, repeatedly press the ‘S’ key to cycle between the
modes until ‘ON’ is displayed. Then press and hold the ‘+’ key to raise the target temperature several
degrees above the room temperature. eg 25 degrees. The CH light on the Relay module should start
to flash Green. Check that the boiler has fired up and any zone valves have moved to their appropriate
positions. Press the ‘S’ key again on the Thermostat to switch it off.
Once you have ascertained that the unit is functioning correctly, push the front cover over the Relay
Module until it clips into place. Finally remove the protective film from the cover.
Please leave this installation manual with the user.
Testing the system
Green
Green
Flashing
Amber or
Green
RF Symbol
Green or
Flashing
Green
Green or
Flashing
Green
Green or
Flashing Green
for NS1003-3