5. Wiring Instructions (cont.)
Circuit 4 Wiring (Platform Lift)
Review the platform lift installation manual and determine how to wire the ITM150 interlock system to
the platform lift’s interlock interface. Note that the Enable Lift is a +12 volt OUTPUT from the interlock
system and an INPUT to the lift system. When at +12 volts the platform lift can be operated.
Connect the interlock yellow Enable wire found on the interlock harness to the lift enable input.
Note: The ITM150 interlock will supply a +12 volt @ 1.8 amp output to allow operation of the lift. Verify that this
is the correct polarity for the platform lift.
The following diagrams show the wiring interface of typical platform lift systems. Be sure to verify the exact wir-
ing interface for the lift system that you have.
Final Steps
Once the harness is completely wired, mount the module and plug in the harness. Test to ensure that it has
been wired correctly and that there are no loose connections.
Braun FMVSS Platform Lift
6
5
9
X
Braun Interlock Connector
Pigtail with blunt-cut wire
Enable Lift yellow wire from
ITM150 interlock. (+12 volts
@ 1.8 amp maximum
when lift is enabled.)
Lift Control Circuit
Vehicle Secure Signal (+12 V Input)
Lift Not Stowed Signal (Ground)
Lift Stowed Signal (Ground)
Not Used
Not Used
X
Pigtail with blunt-cut wire
Enable Lift yellow wire from
ITM150 interlock. (+12 volts
@ 1.8 amp maximum
when lift is enabled.)
Lift Control Circuit
Ricon Series S Platform Lift
7
Red
Enable Lift (At +12 volts
to allow lift to operate)
X
Pigtail with blunt-cut wire
Enable Lift yellow wire from
ITM150 interlock. (+12 volts
@ 1.8 amp maximum
when lift is enabled.)
Lift Control Circuit
Maxon Platform Lift
7
Red/White
Enable Lift (At +12 volts
to allow lift to operate)