3.  Installation Procedures

3.1 Safety Precautions

This interlock product has been designed and manufactured to meet the intended application requirements and 

specifications. Any modifications to the product or to the installation procedure can be dangerous and will void 

InPower’s warranty.

•  Read and understand the instructions in this manual and other manuals before starting the installation.

•  Make sure that the vehicle battery power is disconnected during installation of the Interlock and lift systems.  

•  Reconnect the battery when the system installation is complete.

•  Wear appropriate safety equipment, such as protective eyeglasses, face shield and clothing when installing  

   equipment and handling the battery. 

•  Be careful when working near a battery.  Make sure that the area is well ventilated and that there are no 

   flames near the battery.  Never lay objects on the battery that can short the terminals together.  If battery    

   acid gets in your eyes, immediately seek first aid.  If acid gets on your skin, immediately wash it off with 

   soap and water.

3.2  Getting Started

This manual provides instructions for installing the InPower Model ITM150 Interlock System in the RAM Promas-

ter vans with gasoline engines and with a FMVSS compliant, public use (commercial) platform lift.  It is important 

that you follow these instructions carefully and contact InPower if you need assistance or more information.  

Note that product technical documents are available on InPower’s web site.

This interlock system installation requires additional parts and materials that are not supplied with the interlock 

product.  Identify all required parts before starting the installation and ensure that these items are the correct 

type and quality.

Inspect the interlock product and all other components for damage before starting the installation. Do not per-

form the installation if any problems exist.

Determine the type of interlock interface required for the platform lift. This interlock system provides a +12 volt 

@ 1.8 amps Enable Lift output to allow the platform lift to be operated.  If the lift system is not compatible with 

this interface signal you must take the necessary actions to adapt the lift system interface to the interlock sys-

tem’s interface.  Refer to the lift manufacturer’s installation instructions for further details.

The recommended mounting location for the ITM150 interlock control module is in the center console below the 

shifter, due to the proximity of the wiring connections.  

The unit must not be located in the engine compart-

ment or any location that is not protected from the environment.

WARNING

!

WARNING

!

Summary of Contents for ITM150

Page 1: ...s of the following components 1 ITM150 Control Module 2 7201 046 Chassis Wiring Harness 3 Mounting Screws for shiftlock sensor Note Do not substitute alternate screws for securing the shiftlock sensor...

Page 2: ...ions for installing the InPower Model ITM150 Interlock System in the RAM Promas ter vans with gasoline engines and with a FMVSS compliant public use commercial platform lift It is important that you f...

Page 3: ...be wired Refer to Section 5 Wiring Instructions for details on how to wire the circuits 2 pin Shiftlock Solenoid T Cable 10 pin Shifter T Cable Chassis Wiring Harness 7201 046 20 Inches 22 Inches Lif...

Page 4: ...ifter Always insert and remove connectors by gripping the connectors Do not pull on the wires 3 Unplug 10 pin shifter connector on bottom left side of shifter This should be located just above the 2 p...

Page 5: ...Splice the brown park brake wire from the interlock harness into the orange white park brake wire lo cated on the BCM connector C6 pin 44 Circuit 3 Wiring Lift Door For side sliding door Connect the...

Page 6: ...ng interface of typical platform lift systems Be sure to verify the exact wir ing interface for the lift system that you have Final Steps Once the harness is completely wired mount the module and plug...

Page 7: ...re not being activated by the remote switches e g Lift Door Switch Most troubles are related to wiring problems or switches either failing or becoming out of adjustment Troubleshooting Procedure Step...

Page 8: ...Manuals www braunlift com www techauthority com Ricon Corporation Maxon Lift Corp 7900 Nelson Road 11921 Slauson Avenue Panorama City CA 91402 Sante Fe Springs CA 90670 818 267 3038 562 464 0099 800 3...

Reviews: