Alarm 60800
Fault amplifier axis insertion rod
Fault amplifier axis insertion tube
Fault amplifier axis needle stroke
Fault amplifier axis pickup station nest
Fault amplifier axis pump rotation
Fault amplifier axis pump stroke
Fault amplifier axis swivel arm
Fault amplifier X--Axis
Fault amplifier Y--Axis
Cause
Action
Fault at the servo controller of the in-
dicated drive.
Servo controller is defective.
Motor is defective.
Motor is overheated.
A fuse in the control cabinet has
tripped.
The indicated axis does not operate
smoothly.
Turn main switch off and on again.
Check motor and servo controller.
Let motor cool down.
Check and activate the fuse in the
control cabinet.
Ensure smooth operation of indicated
axis.