22
CPS 220/64/SV
Montage- und Betriebsanleitung
CPS 220/64/SV
Mounting and Operating Instructions
22
5.2. CPUSB 220 / 64 / 16,
CPUSB 220 / 64 / 8 – 1,
CPUSB 220 / 64 / 8 – 9,
CPUSB 220 / 64 / 1 - 2A,
CPUSB 220 / 64 / 1 – 4A
CPUSB 220 / 64 / 1 - 2,5A / 24V
Schutzklasse::
I
Schutzart:
IP 20
Zulässige Umgebungstemperatur:
für das Gerät:
-5°C bis +35°C
Kabeleinführung von oben
5.2. CPUSB 220/64/16,
CPUSB 220/64/8–1,
CPUSB 220/64/8–9
CPUSB 220/64/1–2A,
CPUSB 220/64/1–4 A
CPUSB 220 / 64 / 1 - 2,5A / 24V
Protection class:
I
Protection category:
IP 20
Permissible ambient temperature:
For the device:
-5°C to +35°C
Cable inlets from top
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
600 mm
600
mm
CPUSB 220 / 64 / 8-1
Tiefe
Depth
300 mm
CPUSB 220 / 64 / 1-2A und 1-4A
181 mm
378
mm
Tiefe
Depth
82 mm
CPUSB 220 / 64 / 1-2A und 1-4A
181 mm
378
mm
Tiefe
Depth
82 mm
600 mm
600
mm
CPUSB 220 / 64 / 8-9
Tiefe
Depth
300 mm
CPUSB 220 / 64 / 1-2A und 1-4A
181 mm
378
mm
Tiefe
Depth
82 mm
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
1
2
3
4
CP 4x2A
F
3,15 A
= BL / NM
= DL / M
F
3,15 A
F
3,15 A
F
3,15 A
Tiefe
Depth
400 mm
CPUSB 220 / 64 / 16
800 mm
830
mm
CPUSB 220 / 64 / 16
CPUSB 220 / 64 / 8-1
CPUSB 220 / 64 / 8 - 9
CPUSB 220 /
64 / 1 - 4A
CPUSB 220 /
64 / 1 - 2A
CPUSB 220 /
64 / 1 - 2,5A /
24V
Anschlussspannung
Rated voltage
230V AC ±10% / 216V DC +10% / -15% (wird über die Anlage versorgt)
Supplied via main station
Systemstrom: Intern
System current:Internal
50A
50A
8A
5A (24V)
Gesamt
Total
50A
50A
8A
5A (24V)
Stromkreisweiche
Circuit separating module
-
-
ja / yes
ja / yes
Stromkreismodule
Change over modules
4x2A, 2x4A, 1x6A, 2x2,5A D.E.R.
max. 16
max. 8
1 (je 2A o. 4A)
each 2A or 4A
-
2x2,5A 24V
max. 8
max. 4
-
1
Anzahl freier TE für Optionen
Space for options
14 TE
12 TE
-
-
- bei Funktionserhalt
- with function preservation
2 TE
11 TE
-
-
Max. Anschlussquerschnitt (mm²) für:
Conductor cross section, max. (mm²)
Versorgungsleitung
Power supply
35
35
4
4
Lichtstromkreise
Outgoing to luminaries
4
4
4
4
BUS-Leitung IB2
BUS IB2
4
4
4
4
24V Stromschleife
Outgoing 24V monitoring
-
-
2,5
2,5
Abmessungen: H x B x T (mm)
Dimensions: H x W x D (mm)
830 x 800 x 400
600 x 600 x 300
378 x 181 x 82
378 x 181 x 82
Funktionserhalt (optional)
With function preservation (option)
BRS 08 / BRS 20
BRS 08 / BRS 20
BRS 06
BRS 06
- bei Funktionserhalt
- with fire preservation
1374 x 624 x 434
1374 x 624 x 434
1074 x 624 x 334
1074 x 624 x 334
Kabeleinführungen
Cable inlets
22 x M20
10 x M20
11 x M20
11 x M20
64 x M25
33 x M25
6 x M32
4 x M32
2 x M50