18
e.
Table 1: Multi-speed
K4
K3
K2
K1
Control setting
Parameters
OFF
OFF
OFF
OFF
Speed 0 Setting 0X
E1.00
OFF
OFF
OFF
ON
Speed 1 Setting 1X
E1.01
OFF
OFF
ON
OFF
Speed 2 Setting 2X
E1.02
OFF
OFF
ON
ON
Speed 3 Setting 3X
E1.03
OFF
ON
OFF
OFF
Speed 4 Setting 4X
E1.04
OFF
ON
OFF
ON
Speed 5 Setting 5X
E1.05
OFF
ON
ON
OFF
Speed 6 Setting 6X
E1.06
OFF
ON
ON
ON
Speed 7 Setting 7X
E1.07
ON
OFF
OFF
OFF
Speed 8 Setting 8X
E1.08
ON
OFF
OFF
ON
Speed 9 Setting 9X
E1.09
ON
OFF
ON
OFF
Speed 10 Setting 10X
E1.10
ON
OFF
ON
ON
Speed 11 Setting 11X
E1.11
ON
ON
OFF
OFF
Speed 12 Setting 12X
E1.12
ON
ON
OFF
ON
Speed 13 Setting 13X
E1.13
ON
ON
ON
OFF
Speed 14 Setting 14X
E1.14
ON
ON
ON
ON
Speed 15 Setting 15X
E1.15
f.
Table 2: Piloted acceleration and deceleration
Input 2
Input 1
Acceleration and deceleration time
Parameters
OFF
OFF
Time 1
F0.13 and F0.14
OFF
ON
Time 2
F7.08 and F7.09
ON
OFF
Time 3
F7.10 and F7.11
ON
ON
Time 4
F7.12 and F7.13
g.
Control modes
Code
Designation
Mode
Range Factory value
Changing : motor
ON
F1.10
Control by terminal
block
Two electric wires type 1
0
0
No
Two electric wires type 2
1
Three electric wires type 1
2
Three electric wires type 2
3
Summary of Contents for VFR-091
Page 6: ...6 From 11KW to 160KW ...