1.0 Technical Specifications
Power Supply: Standard is 120Vac, 5A, 50-60Hz (240Vac input
is optional)
Dimensions (L x W x H): 42” x 26” x 62”
Weight: 250 lbs.
Minimum Height Needed for Clearance, with boom retracted: 62”
Maximum Height Needed for Clearance, with boom fully
extended: 104”
Racking screw capability: floor level to 84” high
Minimum Working Clearance for Operation:
o
50” for the “Standard” inoRAC
o
27” for the 90° inoRAC
o
Note*
- Working clearance will vary for “Lever Drive” style.
Maximum Breaker Travel during Racking:
o
11.5” for the “Standard” inoRAC
o
14” for the “Long Travel” inoRAC
Remote operation from 75’ as standard. Longer lengths are
available.