7.7: CCTalk Protocol.
The NV10 supports the CCTalk serial protocol for easy interfacing with host machines that support
this protocol.
To use CCTalk mode (as in Binary mode etc) set DIPswitches 3 and 4 on the user in the Up position
to select ‘Special’ mode on the validators.
The NV8 must have the CCTalk software loaded using the ‘‘advanced’’ option on the Currency
manager program.
Pin out connections on NV10 for CCTalk are shown below (see figure 7) looking at the connection
pins on the NV10 interface connector.
Note:
§
For detailed information and full protocol specification please refer to
Figure 7- CCTalk Connection Pins on the NV10.
The default encryption key will be set to the key code printed on the label on the NV10. If the key is
changed to a new stored key by the host machine, the key can be reset to the default by the following
the steps below.
1. Power off NV10.
2. Set all 4 DIPswitches to the Up position.
3. Apply power (no CCTalk comms).
4. Red LED will now be flashing.
5. Set DIP switches 1 and 2 down.
The code is now reset.