30
For MSR1-18CRN1-NB8(2T0032800278),
MSR1-18CR-NB6,
MSR1-22HRN1-NB8W:Tm=Ts, Tn=Ts-2
For other models, Tm=Ts+1, Tn=Ts
8.4.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and
auto. (As high, medium, low, auto and turbo for 24k models)
Auto fan in cooling mode acts as follow:
8.4.2.4 Outdoor fan speed control (MSR1-21CR-NB6W,
MSR1-24HR-NB6W,
MSR1-24CR-NB6W
models)
Outdoor fan and compressor start up at the same time, outdoor fan stop 30s delay after the
compressor stopped.
The outdoor fan has two speeds, it’s controlled by T3 as following rules:
Low
High
TD
TC
T3
5
4
1
High
Medium
Low
T1-Ts
Summary of Contents for Oasis WOE10C2DB1 / HOE10C2MR83
Page 14: ...12 5 Wiring Diagram 5 1 Indoor Units WOE10C2DB8 WOE13C2DB8 WOE18C2DB8 WOE24C2DB8 ...
Page 15: ...13 5 2 Outdoor Units HOE10C2MR83 HOE13C2MR83 HOE18C2MR83 ...
Page 16: ...14 HOE24C2MR83 ...
Page 48: ...46 9 2 2 Open circuit or short circuit of temperature sensor diagnosis and solution ...
Page 49: ...47 9 2 3 Over current protection occurs 4 times diagnosis and solution ...
Page 51: ...49 9 2 6 Indoor outdoor units communication error diagnosis and solution ...