9.1 Indoor Unit Error Display
For NIN1225C2V31(ID)
Display
LED STATUS
E0
Indoor unit EEPROM parameter error
E1
Indoor / outdoor units communication error
E2
Zero crossing signal detection error(for NIN516C2V31(ID))
E3
Indoor unit fan speed has been out of control
E5
Outdoor unit temperature sensor open circuit or short circuit/Outdoor unit EEPROM
malfunction
E6
Indoor unit temperature sensor open circuit or short circuit
E7
Outdoor unit fan speed has been out of control(for NIN1225C2V31(ID))
P0
IPM malfunction or IGBT over-strong current protection
P1
Over voltage or over low voltage protection
P2
High temperature protection of compressor top diagnosis and solution
P4
Inverter compressor drive error
35
Innovair Corporation
Nexxos Inverter
Summary of Contents for NIN1225C2V31
Page 6: ...2 2 Part names of Indoor Outdoor units 4 Innovair Corporation Nexxos Inverter ...
Page 13: ...5 Wiring Diagram 5 1 Indoor Unit NIN516C2V31 ID 11 Innovair Corporation Nexxos Inverter ...
Page 14: ...NIN522C2V31 ID 12 Innovair Corporation Nexxos Inverter ...
Page 15: ...NIN1225C2V31 ID 13 Innovair Corporation Nexxos Inverter ...
Page 16: ...5 2 Outdoor Unit NIN516C2V31 OD 14 Innovair Corporation Nexxos Inverter ...
Page 17: ...NIN522C2V31 OD 15 Innovair Corporation Nexxos Inverter ...
Page 18: ...NIN1225C2V31 OD 16 Innovair Corporation Nexxos Inverter ...
Page 19: ...For NIN516C2V31 OD 17 Innovair Corporation Nexxos Inverter ...
Page 20: ...For NIN522C2V31 OD 18 Innovair Corporation Nexxos Inverter ...
Page 21: ...For NIN1225C2V31 OD 19 Innovair Corporation Nexxos Inverter ...
Page 39: ...9 2 Outdoor unit error display For NIN516C2V31 OD 37 Innovair Corporation Nexxos Inverter ...
Page 49: ...P U P V 47 Innovair Corporation Nexxos Inverter ...
Page 50: ...P W P N 48 Innovair Corporation Nexxos Inverter ...