TO BE CHECKED BEFORE EACH USE
6
INSPECTION
The inspection intervals are found in the test log.
If there are any doubts concerning the reliable operation of
the fall protection system, it must NO longer be used, and
must be checked by an expert (with written documentation)
If necessary, replace the product.
6.2
ANNUAL CHECKS
INNOTECH standard posts must be inspected at least once a year by a specially trained
technician who is familiar with the fall protection system. The user's safety depends on
the effectiveness and durability of the equipment.
Shorter intervals between inspections may be required, depending on the intensity
of use and the environment (e.g. in corrosive atmospheres, etc.).
Document the verification by the specialist in the inspection log in the instruction manu
-
al, and keep it with the instruction manual.
DANGER TO LIFE through damage to INNOTECH standard posts.
-
INNOTECH standard posts must be in faultless condition.
-
INNOTECH standard post must NO longer be used, if
• Damage or wear to its components are obvious,
• Other defects were observed (loose threaded connections,
deformation, corrosion, wear, etc.),
•
Strain has occurred due to a fall (Exception: provision of first aid),
•
The product identification is illegible.
!
DANGER
Prior to each use, INNOTECH standard posts must be checked visually for any obvious
defects.
Check the entire fall protection systems's suitability for use by using the acceptance
report and test log.