11
EN
EAP-QUAD-11 / Version 181008 / www.innotech.at
10
INSTALLATION SUBSTRUCTURE
10.1
CONCRETE
INNOTECH "BEF-103"
4 x screw-in anchors
The basic prerequisite for professional/proper installation is static load-bearing
con-
struction concrete (solid concrete)
with a
concrete quality of at least C20/25
or a hollow core slab (minimum hollow core cross-section of 25 mm)
with a
concrete quality of at least C 50/60 B4
and use of the original fasteners listed in
this instruction manual.
DANGER OF DEATH as a result of installation on an unsuitable
substructure.
-
Install INNOTECH standard posts on a static load-bearing construction
concrete (solid concrete) with a concrete quality of at least C20/25.
-
DO NOT install on screed, levelling concrete,
blinding concrete etc.
-
In case of doubt, the installation substrate must be checked by a
structural engineer or by the manufacturer.
!
DANGER
INNOTECH "BEF-104"
4 x concrete anchors