SAFETY INSTRUCTIONS

3.1

ALLGEMEIN

The following safety instructions and the current state of the art must be 
taken into consideration.

3.1

GENERAL

 

-

The fall protection system may be installed only by specialised experts familiar 
with the fall protection system, and in accordance with the current state of the art.

 

-

The protective equipment may be used only by people who are 
• trained in the use of "personal protective equipment" (PPE). 
•  are in good physical and mental health. Medical conditions such as cardiovascular 

problems, intake of medicines, consumption of alcohol, etc. negatively affect the 

safety of the user.

 

-

• are familiar with the locally applicable safety regulations.

 

-

During installation/use of the fall protection system, the respective accident preven-
tion regulations (e.g. working on roofs) must be complied with.

 

-

Understand and accept the capabilities, restrictions, and risks of the protective equip-
ment.

 

-

A plan must be available that specifies rescue procedures for all possible emergencies

.

 

-

Before starting work, ensure that no objects can fall to the ground from the work 
site. The area below the work site (pavement, etc.) must be kept clear.

 

-

You should plan, install, and use the anchorage point in such a way that no one can 
fall over the edge if the personal protective equipment (PPE) is used properly.  
(See planning documents on www.innotech.at)

 

-

At the access to the roof fall protection system, you must document the positions 
of the attachment devices by means of plans (e.g. top view of the roof).

 

-

If following the certification of the fall protection system, structural changes are 

carried out in the immediate vicinity of the fall protection system, it must be ensured 

that these changes do not affect the security of the installed fall protection system! 

Where there is any doubt, consult a structural engineer or the manufacturer.

 

-

After being subjected to the stress of a fall, the use of the fall protection system 
must be stopped, and it must be checked by a specialised expert (component parts, 
attachment to the substructure, etc.).

 

-

Do not make any changes to the fall protection system.

 

-

If used on sloping roofs, roof avalanches (ice, snow) must be avoided by means of 
suitable devices to prevent snow from sliding.

Summary of Contents for EAP-QUADRAT-11

Page 1: ...endido las instrucciones de uso en el idioma del pa s ES PT ATEN O O uso do produto INNOTECH apenas permitido depois de ter lido e compreendido na totalidade as instru es de uso na respetiva l ngua na...

Page 2: ...MATERIAL 6 5 PRODUCT SUITABILITY APPROVAL 7 6 INSPECTION 8 7 WARRANTY 9 8 SIGNS MARKINGS 9 9 DIMENSIONS 10 10 INSTALLATION SUBSTRUCTURE 11 11 INSTALLATION TOOL 13 12 INSTALLATION 13 13 STRESS DIRECTIO...

Page 3: ...orrect Incorrect For a POTENTIALLY dangerous situation that can cause serious physical injuries or death For a POTENTIALLY dangerous situation that could lead to minor physical injuries and damage to...

Page 4: ...ble emergencies Before starting work ensure that no objects can fall to the ground from the work site The area below the work site pavement etc must be kept clear You should plan install and use the a...

Page 5: ...he personal protective equipment used including deflection of the cable body height 1 m safety margin Correct use of the individual elements including personal protective equipment must be ensured bec...

Page 6: ...TS MATERIAL A Instruction manual B Lubricant Weicon AntiSeize ASW10000 C INNOTECH Standartposts Stainless steel AISI 304 D M16 locking nuts Stainless steel AISI 304 E M16 hex nuts Stainless steel AISI...

Page 7: ...8 Restraint systems Workplace positioning systems Fall arrest systems Rescue systems DANGER OF DEATH from incorrect use Use INNOTECH standard posts ONLY for personal safety NEVER hang loads from INNOT...

Page 8: ...be required depending on the intensity of use and the environment e g in corrosive atmospheres etc Document the verification by the specialist in the inspection log in the instruction manu al and kee...

Page 9: ...been deformed For system installation and for components planned and installed under the responsibility of specialised installation companies INNOTECH assumes neither responsibility nor warranty in th...

Page 10: ...10 EAP QUAD 11 Version 181008 www innotech at EN mm 9 DIMENSIONS Standard length L 300 400 500 600 mm 105 105 205 q 235 q 4 L 8x O 10 5 6x O 13 O 13...

Page 11: ...25 mm with a concrete quality of at least C 50 60 B4 and use of the original fasteners listed in this instruction manual DANGER OF DEATH as a result of installation on an unsuitable substructure Inst...

Page 12: ...CONSTRUCTION INNOTECH BEF 205 4 x fastening bolts 8 0 x 120 mm 8 x fastening bolts 6 0 x 40 mm INNOTECH BEF 307 Screw fastening for OSB PLATE 4 x special anchors INNOTECH BEF 209 4 x fastening bolts...

Page 13: ...otech at 10 3 TRAPEZOIDAL SHEETING 10 INSTALLATION SUBSTRUCTURE INNOTECH BEF 307 BEF 307 3 TRAPEZOIDAL SUPPORTING SHEET 4 x special anchors 2 x stabilisation bar 356 310 250 INNOTECH BEF 307 TRAPEZOID...

Page 14: ...11 Version 181008 www innotech at EN 11 INSTALLATION TOOL mm SW 24 2x 12 MONTAGE 1 DANGER OF DEATH if NOT properly installed Install INNOTECH standard posts properly as specified in the instruction ma...

Page 15: ...15 EN EAP QUAD 11 Version 181008 www innotech at 12 INSTALLATION FINISHED 2x 2 3 0 5 2 mm...

Page 16: ...UNAPPROVED stress directions Only use INNOTECH Quadrat in the approved stress directions DANGER 14 WASTE DISPOSAL Do NOT dispose of the fall protection system in the house waste As per national requir...

Page 17: ...tick as appropriate EAP single anchorage points ANCHORAGE POINTS of a horizontal lifeline system in accordance with EN 795 2012 TYPE C Specialist Company address OPTIONAL For set up of a horizontal l...

Page 18: ...n manual documentation of the anchorage points photo documentation and test logs have been transferred to the client building owner and have been made available to the user Near the system access to t...

Page 19: ...inspection logs etc is Overview showing the position of the anchorage device Mark the areas where there is a break through hazard e g light domes and or roof lights The maximum limit values of the anc...

Page 20: ...TEM INSPECTION CLIENT Specialist Company address CONTRACTOR Specialist Company address INSPECTION POINTS checked and in order DEFECTS DETECTED Description of defects measures DOCUMENTATION Instruction...

Page 21: ...Mobility of the attached parts EAP SZH EDLE etc HORIZONTAL LIFELINE SYSTEM Attention For horizontal lifeline systems the inspection log of the AllinOne TYPE instruction man ual see copy template in th...

Page 22: ...22 EAP QUAD 11 Version 181008 www innotech at EN 18 DEVELOPMENT SALES INNOTECH Arbeitsschutz GmbH Laizing 10 4656 Kirchham Austria www innotech at...

Reviews: