The Safety Lock did not activate within 20 minutes
• Check the setting of the Control Unit as advised in section 8. If the Safety Lock was not activated,
redo the setup process as described in section 5.
Intelligent Timer did not cut off the electricity supply in 3 hours
• In some cookers that are operated by touch or that have a clock, and with the SGK500-3 model in
all electric cookers, the Intelligent Timer will not start when a hotplate is on a very low setting.
What to do when changing the cooker to a new one?
• If your hob type has changed (ie. you used to have an electric cooker, and now you have a dual-fu-
el cooker with gas burners) change the hob type setting (see section 7).
• Return the Intelligent Heat Sensor to its factory settings, see section 4. If it is installed higher than
65cm (26’’) for cookers with electric burners or 70cm (28’’) for gas burners, set the sensitivity level
manually (see section 9).
What to do when replacing the Intelligent Heat Sensor or the Control Unit with a new
one?
• See www.innohome.com for device pairing instructions.