Setup DIP switch position for Normally Closed or Normally Open
output of 3rd party control unit.
Closing the charging station cover
After the wiring installation is done, close the charging station cover.
1. Push the cover on horizontally towards the back part of the
charging station. Make sure the clips inside the top part of the
cover attach properly in the holes on the back part of the unit.
2. Attach the screws on the bottom of the charging station cover.
3. Attach the screw on the top of the charging station cover
Taking the charging station into use
Test measurements must be performed before taking the
charging station into use.
Connecting the power supply
Before connecting the power supply, make sure that all the
needed cable installations are completed and that the earth
resistance measurements have been made according to local
regulations.
1. Remove the signaling warning tag from the circuit breaker or
power supply switch of the charging station.
2. Remove the dedicated lock or other preventive measures from
the circuit breaker or power supply switch.
3. Connect the power supply to the charging station by operating
the circuit breaker.
4. Test the functionality of Type-A RCD by pressing RCD test
button.
Measurements after power supply connection
Verify the operation of the charging station after the power
supply has been connected.
1. Check the indicators of the charging station. Refer to LED
descriptions for more details.
2. It is recommended to use EV charging station installation
tester to ensure functionality.
Testing the charging station in normal use
1. Make sure all the wires have been connected correctly and
the charging station cover is attached.
2. Connect vehicle charging cable to the charging station.
3. Connect charging cable to vehicle
4. Make sure that the LED in the charging station switches to
charging mode. See LED indicators for more details.
5. Check that the charging indicator of the vehicle is activated.
External input connection (Charlie-3)
Charlie-3 has input connector for potential free control signal
from 3rd party units. When signal occurs in input, Charlie-3 will
limit maximum charging current into 8A. When signal returns to
normal state, maximum charging current returns into predefined
value.
Connect potential free output of control unit to connector pins
CC+ and CC-
Danger:
Test measurements are performed using high
voltages.
Danger:
Test measurements are performed using high
voltages.
Before this test, make sure that the charging station has
been tested by using testing equipment.
Innohome | Charlie electric vehicle charging station | Installation and User Guide
DIP
contact
max current
note
DIP setting defines
8A
Use this setting
if no external
control is used
DIP setting defines
8A
10