16
Control panel and peripherals
Anti-intrusion control panels
COMMUNICATION
I-BUS
The control panel monitors continuously the traffic on the I-BUS line.
If no signals (control panel and peripheral signals) are detected on the I-BUS for over 90
seconds, the keypad screens will show the warning opposite. The screen will show:
1. keypad model
2. keypad firmware version
3. error type
4. the number of the keypad and the number of the integrated reader
In this case, the installer must first check that cable “D” of the I-BUS is connected properly.
Then check the proper operating capacity of the I-BUS and the general integrity of the entire
system.
If the message opposite appears on the keypad screen, it means that I-BUS is operating
properly but cannot communicate with the keypad in question.
This indicates that the keypad is not present in the system configuration.
Note
One of the two messages shown above may also appear during control panel firmware updates.
If you are using an Alien keypad, the above-mentioned information will be shown on bar at
the bottom of the home page.
2-2
Environmental Conditions
Prime control panels must not be installed outdoors and operate properly under the following
conditions:
•
Temperature
:
from -10° to +40°C
•
Maximum humidity
:75% (without condensation)
•
Environmental class
:II
The peripherals must not be installed outdoors and operate properly under the following
conditions:
•
Temperature
:
from -10° to +40°C
•
Maximum humidity
:75% (without condensation)
•
Environmental class
:II
The nBy/S reader is suitable for outdoor installation and operates best under the following
conditions:
•
Temperature
:
from -25° to +70°C
•
Maximum humidity
:93% (without condensation; for 30 days per year granting that the
relative humidity can touch points of 95% without being subject to condensation)
•
Protection grade
:IP 34
•
Environmental class
:IV
2-3
Peripherals
The Prime anti-intrusion system provides for the use of devices connectible to the control
panel via I-BUS:
• keypads (Joy, Aria/HG, nCode/G, Concept/G, Alien)
• readers (nBy)
• expansions (Flex5)
• transceivers (Air2-BS200)
• sounders/flashers (Ivy-B)
• 2G/3G/4G communicators (Nexus)
• isolators (IB200)
• heat sensors
• home-automation modules
ATTENTION!
The connectible peripherals must have firmware versions higher than or equal to 5.00.
- JOY/MAX -
FW RELEASE X.YZ
NO COMMUNICATION
K01 P14
- JOY/MAX -
FW RELEASE X.YZ
NOT ENROLLED
K01 P14
Summary of Contents for Prime060L
Page 4: ...4 Anti intrusion control panels...
Page 35: ...Installation manual 35...