Installation manual
Installation
21
Once powered up, the panel will charge and monitor the batteries automatically. The control
panel tests the efficiency of the batteries by simulating load current demand at regular 4
minute intervals. If the control panel detects a voltage inferior to 10.4V (battery inefficient), it
will generate an “Low Battery” event that will not clear until the voltage restores to over
11.4V.
In this case the yellow LED on the keypad will light up. To view the fault event, work through
the following steps:
User menu
, View , Faults
3-1-4
Thermal probe
A thermal probe
[L]
is available for compensation of the battery charge voltage based on the
battery temperature. The thermal probe protects against battery overheating and consequent
permanent damage to the battery.
To connect the thermal probe, work through the following steps:
1. Disconnect the battery.
2. Connect the thermal probe to the connector on the power supply
[M]
(
Table 2-5: Con-
trol panels - description of parts, D
).
3. Attach the thermal probe to the battery
[N]
, in such a way as to provide optimized heat-
transfer measurements.
3-1-5
Opening and closing the control panel
To gain access to the control panel, it is necessary to remove the front plate of the metal
enclosure and proceed as follows:
1. Type-in the installer code on a keypad and press
OK
. Access to the installer menu will
inhibit the activation of the output and any report calls associated with the “Open-
panel” event.
2. Remove the 2 screws and the metal front plate.
3. Insert the Maintenance jumper (refer to
paragraph 3-1-9 Maintenance status
) and carry
out the necessary work.
Once maintenance has been completed, work carefully through the following steps.
1. Remove the Maintenance jumper.
2. Using the 2 screws, secure the front plate in place.
3. Exit the Installer menu.
Note
If you exit the Installer menu before replacing the front plate, the control panel will not generate an
“Open-panel” event immediately.
However, the system will generate an open-panel event, if the front plate is not replaced within 15
seconds of closing the open-tamper microswitch.
3-1-6
Connecting the Land-line (PSTN)
Connect the land line (PSTN) to terminals 39 and 40 on the control panel motherboard (
Table
2-7: Mother board - terminal board, 39-40
).
If you are installing the control panel in a place where the land line (PSTN) service is not
available, or if you wish to increase the level of security of the system, these terminals also
accept a GSM interface (such as SmartLinkAdv) which simulates the analogue land-line.
SmartLinkAdv is a telephone dialer manufactured by INIM Electronics and is available in two
versions, model G and model GP. Both devices monitor the analogue land line and in the event
of line-down conditions (e.g. wire-cutting) simulate the analogue land line and allow the
control panel to switch incoming/outgoing calls to the GSM network.
You can also use the terminals on the SmartLinkAdv board to extend the functions provided
by the Prime system. Following are several examples:
• Arming/Disarming the system over-the-phone using a cost-free call or SMS text
By connecting one of the Prime board terminals programmed as “follow zone” to an output
on the SmartLinkAdv board, it will be possible to arm or disarm the Prime system via SMS
text.
In a similar way, using a terminal programmed as a “switching zone”, it will be possible to
arm or disarm the control panel simply by means of a recognized incoming call.
• Receive an SMS text in the event of Control panel alarm
By connecting one of the Prime control panel alarm outputs to a SmartLinkAdv input, it will
be possible to receive alarm communications via SMS text. The SMS text, which is
programmable, can be automatically forwarded to ten different contact numbers.
All the functions of the Prime system which use the PSTN line (voice dialer, answerphone,
alarm receiving centre and teleservice) can be managed completely over the GSM network by
Faults present
Low battery
Smart
LinkAdv
Control