Installation
Anti-intrusion control panels
the SmartLinkAdv. Of particular interest is the possibility of carrying out teleservice
maintenance also through the GSM network.
Note
If an ADSL line is present, it is necessary to connect the control panel downstream of the ADSL filter on
the line dedicated to telephone equipment (this line is clearly indicated on the filters).
If the control panel is not equipped with a SmartLogos30M voice board, voice calls will
produce a continuous beep for 30 seconds.
3-1-7
PC Link
The link with the control panel is required during writing on the control panel and reading from
control panel. This can be achieved in various ways:
•
USB
: this is a direct connection with the control panel via the USB port.
The link functionality depends on the installation of the drivers for communication via USB.
These are available in the folder: C:\Program Files (x86)\Inim\Prime\drivers\USB
•
LAN and WiFi networks
,this type of link is obtained via the network modules of the
Prime control panel:
- LAN card integrated in the control panel for the connection to Ethernet networks
-
PrimeLAN
, optional board for connections to Ethernet networks
-
PrimeWiFI
, optional board for Wi-Fi connection
Communication functionality is subject to the configuration of the network itself. It is strongly
recommends that you contact the network administrator for the correct configuration.
•
Inim Cloud
: the connection of control panels to the Cloud service is achieved via LAN or
GSM with no need to make configurations in the network on which the control panel is
deployed. In particular, it is not necessary to program a router to perform port-forwarding
and the like in order to reach the control panel. No network programming is required on
the network boards, since these boards are programmed by default with the DHCP enabled
(option that allows the automatic assigning of an IP address to the devices on the
network). The type of connection available can be configured through the “Settings,
Communication ports” section of the menu, “Communication type” tab.
For details regarding the connection, refer to the Prime/STUDIO software manual.
3-1-8
Connecting the SmartLogos30M board
For proper installation of the board, work carefully through the following steps.
1. Completely shutdown all power to the control panel by disconnecting the primary power
source and the lead battery.
2. Insert the board into the appropriate connector (
Table 2-6: Mother board - description
of parts, B
).
3. Power up the system from the mains and reconnect the lead batteries.
3-1-9
Maintenance status
Maintenance status is signalled on the first line of keypad displays by the word “Maintenance”
and the keypad address. In the case of a keypad with an enabled integrated proximity reader,
the reader address will also be shown.
During maintenance mode, the control panel:
• Forces the relay output on the motherboard (
Table 2-7: Mother board - terminal board, 1-
2-3
) to stand-by status.
• Does not activate the outputs (and will force any active outputs to stand-by status)
triggered by:
•• alarm or zone/partition tamper
•• peripheral tamper
•• open/dislodged panel tamper
• It allows initialization of the keypad address programming phase.
• It allows initialization of the reader address programming phase.
• It initializes automatically the auto-enrolling process of the peripherals connected to the
BUS at 10 seconds intervals. The installer programs the addresses of the peripherals
connected to the BUS and, at 10 second intervals, the control panel enrolls in the
configuration the peripherals it finds.
• If there are any lost devices, the BUS will not be reset repeatedly in an attempt to retrieve
them.
• It continues, except for the points mentioned above, to be operational in all of its
functions.
During maintenance mode, the Alien keypad:
Mainten K03 P05
Armed Away mode
Keypad address
Reader address