background image

Installation

7

Installation and programming manual

2-3

“Test” function

This function has been implemeted in order to make the detector easy to set up.
The function can be activated disconnecting and connecting again the jumper

(

table 3, S

); within a minute the function will be operative. In this mode the LED

will be lighted for each detection. Below the meanings of the LED's:

Red LED 

(

table 3, O

): switch on when there is an alarm or tamper situation.

Yellow LED 

(

table 3, P

): switch on when the microwave detects a motion.

Left green LED 

(

table 3, Q

): switch on when the upper PIR detects a motion.

Right green LED 

(

table 3, R

): switch on when the lower PIR detects a motion.

After about 4 minutes the test mode is automatically switched off, and the LED are

deactivated (

paragraph 2-4 “Inhibition” function

).

Note

Be sure to have screwed up the cover with Fresnel lens before perform the tests.

LEDs activation can be seen through the lens.

Once performed detection and radio transmission range tests, the detector is

ready to work.

Note

LEDs are active only in test mode.

In working mode the LEDs are automatically deactivated. In order to verify if the

detector is working properly, remove the front cover disconnect and connect again

the jumper to activate the testing mode; at the end screw the cover up.

2-4

“Inhibition” function

In working mode (LEDs deactivated) the function inhibition is automatically

activated in order to safe battery life. This implies that if the detector has been

installed in a populated area, the detector will no switch the alarm relay if the

detection area is free for three minutes at least.
This function avoid that the detector triggers the alarm relay continuously.
In order to verify if the detector is working properly, wait at least three minutes

after each detection.

3

INSTALLATION

WARNING

It is important to evaluate the installation site previously. Bush close to the

detector might cause false alarm.
The detector is equipped with UV filters in order to avoid problems due to

sunshine rays. Anyway, if it is possible, do not direct the detector versus the sun. 

3-1

Placement

Start the “test” mode (

paragraph 2-3 “Test” function

), in order to obtain a real

simulation, keep out the protected area, and avoid any crossing into it.
After 30÷40 seconds without events, come in to the detection area and, looking

the red LED, verify if the detector works correctly.
After the detection, wait at least 7÷8 seconds before the next detection. Refer to

the coverage diagram to estimate the detection area (

table 5 "Top view"

 and 

table

6 "Side view"

).

Environmental conditions are important elements to be evaluated during the

installation. Bump, bottomland or slops can modify the performances of the

detector.
If into the detection area any medium size animal can walk, it is suggested to

choose carefully the installation height in order to avoid false alarms.

Summary of Contents for Air2-OTT100W

Page 1: ...1 Installation and programming manual Air2 OTT100W Triple technology wireless detector for outdoor use Installation and programming manual ...

Page 2: ...s 6 2 3 Test function 7 2 4 Inhibition function 7 3 Installation 7 3 1 Placement 7 3 2 Installation procedure 8 4 Programming 8 5 Maintenance and periodic checks 9 6 Disposal and scrapping 9 Appendix Declaration of conformity 10 Copyright The information contained in this document is the sole property of INIM Electronics s r l No part may be copied without written authorization from INIM Electroni...

Page 3: ...w consumption power supply range 3 to 9V Test function to signalling each alarm by LED blinking auto power off after 4 minutes Tamper and dislodgement system Inhibition LED and transmitting function for battery life saving always on Two PIRs and one microwave MW programmable sensors AND OR selectable function Mechanism for horizontal coverage adjustment Precision adjustment of lower beam patented ...

Page 4: ... L and U brackets fixing L External screw for L and U brackets fixing M Base enclosure screw Table 3 Electronic part description N Terminal board for wire connection O Red LED for radio transmission P Yellow LED for MW Q Left green LED for each higher PIR detection R Right green LED for each lower PIR detection S Jumper T Microwave sensitivity adjustment trimmer U Higher infrared sensor PIR 1 V Lo...

Page 5: ...arately U shaped brackets L shaped brackets 2 FUNCTIONING 2 1 Detection range ADJUSTMENT Use the trimmer MW table 3 T to adjust the microwave sensitivity the sensitivity is increased turning it clockwise By using the knob table 2 F it is possible to move the PIR2 lower in order to obtain different ranges from 3m to 12m Table 4 Technical specifications of Air2 system Operating frequency range 868 0...

Page 6: ...evant working examples Table 6 Side view PIR2 position Distance A 3 m B 4 m C 7 m D 10 m E 12 m 1 2m 3m 4m 7m 10m 12m E A Table 7 Working examples A Detector B Protected area limit C The pet is detected only by two of the three sensors lower PIR and MW No alarm D The person is detected by all three sensors upper PIR lower PIR MW Alarm E The person is detected by two sensors upper PIR and MW No ala...

Page 7: ...e LEDs deactivated the function inhibition is automatically activated in order to safe battery life This implies that if the detector has been installed in a populated area the detector will no switch the alarm relay if the detection area is free for three minutes at least This function avoid that the detector triggers the alarm relay continuously In order to verify if the detector is working prop...

Page 8: ...nto the holes 7 Screw up the case with the screws Pay attention to not damage anti tam per switch support knock out Note Use the lower hole to fix the hermetic casing on the wall 8 Enroll the detector refer to Air2 BS200 transceiver installation manual 9 Insert the o ring gasket table 2 I into its seat located on the electronic holder table 2 D Note Pay attention to not stretch out the o ring gask...

Page 9: ...ove it 2 Disconnect the detector disconnect all the terminals on the terminal block 3 Divide the parts by type and dispose of them in accordance with applicable laws ATTENTION Do not dispose of the components or any other product material in the environment Seek the assistance of companies authorised to dispose of and recycle waste materials Table 9 Sensor programming DIP 3 OFF ON DIP 4 OFF Triple...

Page 10: ...INIM Electronics s r l dichiara che questo Air2 OTT100W è con forme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE Lietuviž Šiuo INIM Electronics s r l deklaruoja kad šis Air2 OTT100W atitinka esminius reikalavimus ir kitas 1999 5 EB Direktyvos nuostatas English Hereby INIM Electronics s r l declares that this Air2 OTT100W is in compliance with th...

Page 11: ...11 Installation and programming manual Notes ...

Page 12: ...via Dei Lavoratori 10 63076 Monteprandone AP Italy Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ISO 9001 Quality Management certified by BSI with certificate number FM530352 DCMIINIEA2OTT100W 120 20171222 ...

Reviews: