8
Programming
Air2-OTT100W
Note
The maximum coverage range, 12m, is reached when the detector is installed at
about 120cm (height).
Do not obscure partially or completely the detector’s field of view.
Place the detector no less than 2m away from the Air2-BS200 transceiver.
3-2
Installation procedure
1.
Unscrew the screw for the cover enclosure (
table 2, J
).
2.
Remove the cover with lens (
table 2, E
).
3.
Unscrew the fixing screws (
table 2, M
) of the detector to the waterproof
rear casing.
4.
Fix the hermetic casing (
table 2, C
) on the wall, or on a pole (be sure the
pole is stable and ripple free).
POLE FIXING
5.
Fix the “L” shape bracket (
table 2, B
) behind the hermetic casing with one
screw (
table 2, K
).
Note
Use the upper hole to fix the case to the “L” shaped bracket.
6.
Position the two “U” (
table 2, A
) shaped bracket around the pole.
7.
Block them with the inner screws (
table 2, L
) and the external screws (
table
2, K
).
WALL FIXING
5.
Perforate the wall in correspondence of the holes on the casing.
6.
Insert the wall plugs into the holes.
7.
Screw up the case with the screws. Pay attention to not damage anti tam-
per switch support knock-out.
Note
Use the lower hole to fix the hermetic casing on the wall.
8.
Enroll the detector (refer to Air2-BS200 transceiver installation manual).
9.
Insert the o-ring gasket (
table 2, I
) into its seat located on the electronic
holder (
table 2, D
).
Note
Pay attention to not stretch out the o-ring gasket during its installation.
10. Couple the detector and the hermetic casing then screw (
table 2, M
).
11. Run the range settings (PIR 2 position adjustment, MW sensitivity, PIRs
sensitivity). See
paragraph 2-1 Detection range
.
12. Close the detector with the front cover with Fresnel lens as shown opposite.
13. Screw up the metric screw (
table 2, J
).
14. Wait 30 seconds without moving the detector.
15. Proceed with the verification and programming phases.
4
PROGRAMMING
In order to make the detector suitable for outdoor applications, a single sensor
adjustment system has been implemented.
In the tables below are shown the DIP switch configurations (
table 3, W
):
Table 8: Infrared sensitivity adjustment
OFF
ON
DIP 1
PIR 1 sensitivity LOW
PIR 1 sensitivity HIGH
DIP 2
PIR 2 sensitivity LOW
PIR 2 sensitivity HIGH