background image

8

Programming

Air2-OTT100W

Note

The maximum coverage range, 12m, is reached when the detector is installed at

about 120cm (height).

Do not obscure partially or completely the detector’s field of view.

Place the detector no less than 2m away from the Air2-BS200 transceiver.

3-2

Installation procedure

1.

Unscrew the screw for the cover enclosure (

table 2, J

).

2.

Remove the cover with lens (

table 2, E

).

3.

Unscrew the fixing screws (

table 2, M

) of the detector to the waterproof

rear casing.

4.

Fix the hermetic casing (

table 2, C

) on the wall, or on a pole (be sure the

pole is stable and ripple free).

POLE FIXING

5.

Fix the “L” shape bracket (

table 2, B

) behind the hermetic casing with one

screw (

table 2, K

).

Note

Use the upper hole to fix the case to the “L” shaped bracket.

6.

Position the two “U” (

table 2, A

) shaped bracket around the pole.

7.

Block them with the inner screws (

table 2, L

) and the external screws (

table

2, K

).

WALL FIXING

5.

Perforate the wall in correspondence of the holes on the casing.

6.

Insert the wall plugs into the holes.

7.

Screw up the case with the screws. Pay attention to not damage anti tam-

per switch support knock-out.

Note

Use the lower hole to fix the hermetic casing on the wall.

8.

Enroll the detector (refer to Air2-BS200 transceiver installation manual).

9.

Insert the o-ring gasket (

table 2, I

) into its seat located on the electronic

holder (

table 2, D

).

Note

Pay attention to not stretch out the o-ring gasket during its installation.

10. Couple the detector and the hermetic casing then screw (

table 2, M

).

11. Run the range settings (PIR 2 position adjustment, MW sensitivity, PIRs

sensitivity). See 

paragraph 2-1 Detection range

.

12. Close the detector with the front cover with Fresnel lens as shown opposite.
13. Screw up the metric screw (

table 2, J

).

14. Wait 30 seconds without moving the detector.
15. Proceed with the verification and programming phases.

4

PROGRAMMING

In order to make the detector suitable for outdoor applications, a single sensor

adjustment system has been implemented.
In the tables below are shown the DIP switch configurations (

table 3, W

):

Table 8: Infrared sensitivity adjustment

OFF

ON

DIP 1

PIR 1 sensitivity LOW

PIR 1 sensitivity HIGH

DIP 2

PIR 2 sensitivity LOW

PIR 2 sensitivity HIGH

Summary of Contents for Air2-OTT100W

Page 1: ...1 Installation and programming manual Air2 OTT100W Triple technology wireless detector for outdoor use Installation and programming manual ...

Page 2: ...s 6 2 3 Test function 7 2 4 Inhibition function 7 3 Installation 7 3 1 Placement 7 3 2 Installation procedure 8 4 Programming 8 5 Maintenance and periodic checks 9 6 Disposal and scrapping 9 Appendix Declaration of conformity 10 Copyright The information contained in this document is the sole property of INIM Electronics s r l No part may be copied without written authorization from INIM Electroni...

Page 3: ...w consumption power supply range 3 to 9V Test function to signalling each alarm by LED blinking auto power off after 4 minutes Tamper and dislodgement system Inhibition LED and transmitting function for battery life saving always on Two PIRs and one microwave MW programmable sensors AND OR selectable function Mechanism for horizontal coverage adjustment Precision adjustment of lower beam patented ...

Page 4: ... L and U brackets fixing L External screw for L and U brackets fixing M Base enclosure screw Table 3 Electronic part description N Terminal board for wire connection O Red LED for radio transmission P Yellow LED for MW Q Left green LED for each higher PIR detection R Right green LED for each lower PIR detection S Jumper T Microwave sensitivity adjustment trimmer U Higher infrared sensor PIR 1 V Lo...

Page 5: ...arately U shaped brackets L shaped brackets 2 FUNCTIONING 2 1 Detection range ADJUSTMENT Use the trimmer MW table 3 T to adjust the microwave sensitivity the sensitivity is increased turning it clockwise By using the knob table 2 F it is possible to move the PIR2 lower in order to obtain different ranges from 3m to 12m Table 4 Technical specifications of Air2 system Operating frequency range 868 0...

Page 6: ...evant working examples Table 6 Side view PIR2 position Distance A 3 m B 4 m C 7 m D 10 m E 12 m 1 2m 3m 4m 7m 10m 12m E A Table 7 Working examples A Detector B Protected area limit C The pet is detected only by two of the three sensors lower PIR and MW No alarm D The person is detected by all three sensors upper PIR lower PIR MW Alarm E The person is detected by two sensors upper PIR and MW No ala...

Page 7: ...e LEDs deactivated the function inhibition is automatically activated in order to safe battery life This implies that if the detector has been installed in a populated area the detector will no switch the alarm relay if the detection area is free for three minutes at least This function avoid that the detector triggers the alarm relay continuously In order to verify if the detector is working prop...

Page 8: ...nto the holes 7 Screw up the case with the screws Pay attention to not damage anti tam per switch support knock out Note Use the lower hole to fix the hermetic casing on the wall 8 Enroll the detector refer to Air2 BS200 transceiver installation manual 9 Insert the o ring gasket table 2 I into its seat located on the electronic holder table 2 D Note Pay attention to not stretch out the o ring gask...

Page 9: ...ove it 2 Disconnect the detector disconnect all the terminals on the terminal block 3 Divide the parts by type and dispose of them in accordance with applicable laws ATTENTION Do not dispose of the components or any other product material in the environment Seek the assistance of companies authorised to dispose of and recycle waste materials Table 9 Sensor programming DIP 3 OFF ON DIP 4 OFF Triple...

Page 10: ...INIM Electronics s r l dichiara che questo Air2 OTT100W è con forme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE Lietuviž Šiuo INIM Electronics s r l deklaruoja kad šis Air2 OTT100W atitinka esminius reikalavimus ir kitas 1999 5 EB Direktyvos nuostatas English Hereby INIM Electronics s r l declares that this Air2 OTT100W is in compliance with th...

Page 11: ...11 Installation and programming manual Notes ...

Page 12: ...via Dei Lavoratori 10 63076 Monteprandone AP Italy Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ISO 9001 Quality Management certified by BSI with certificate number FM530352 DCMIINIEA2OTT100W 120 20171222 ...

Reviews: